background image

10A

10B

0

20

40

60

80

100

120

600

700

800

900

1000

1100

1200

542

540

227

270

118

64

72

105

EN

EN

TECHNICAL CHARACTERISTICS

The 

M1805-X

 is an automation with anodized aluminum chassis, developed to use in 

pedestrian

doors up to 120kg.

• The control board is microprocessor controlled and does self programming. Users only 

need to select the speeds and the pause time.

• The automation has obstacle detection function and self-protection for overheating, 

overvoltage and overcurrent.

• Power Supply

230Vac 50Hz

• Potency

65W/100W

• Door Type

Opening to the right or left

Internal or external opening

• Opening angle

90

°

• Opening speed (90°)

Adjustable

• Closing speed (90°)

Adjustable

• Pause time in opening

0.5 - 10 seconds

• Manual strength

<30N

• Consumption

65W/100W

• Operating temperature

-30

°

Ϲ to +50

°

Ϲ

• Door's maximum weight

120kg

• Accessories output

500mA

• Eletric lock output

600mA

03. THE AUTOMATION

Door maximum

weight: 120kg

WIDTH/WEIGHT RATIO

Door weight (kg)

Door width (mm)

03. THE AUTOMATION

TECHNICAL CHARACTERISTICS

Motor

* Arm

* Arm for interior opening

* Arm for external opening

Fixing 

screws

Profile 

cover

Fixing 

screws

Profile for fixing 

to the door

Dimensions in mm

Содержание M1805-X

Страница 1: ...V1 0 REV 10 2021 M1805 X M1805 X EN USER INSTALLER MANUAL...

Страница 2: ...This marking on the product or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should not be disposed of as other household wast...

Страница 3: ...enced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid 01 SAFETY INSTRUCTIONS t...

Страница 4: ...utomatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resett...

Страница 5: ...D 24 1 2 3 4 5 6 1 2 3 4 5 6 7 RAP5M PRO EN 02 CONNECTION SCHEMES COMPONENTS CONNECTION 2 M1601 Radar Control board Magnetic lock Electric lock MDL1805 module Battery 24V Automatism Radar 12V 12V The...

Страница 6: ...18 19 20 21 22 1 2 3 4 5 6 7 8 9 10 11 EN 02 CONNECTION SCHEMES RADARS AND PROGRAM SELECTOR CONNECTION PROGRAM SELECTOR EXTERNAL Radar M1601 INTERNAL Radar M1601 red white purple orange green green w...

Страница 7: ...gular doors with interlocking connected to each other you should be aware these connections Only when one of the doors is closed the other can open When using this function if one of the doors is disc...

Страница 8: ...Combination to turn on LED s To turn on off any of the LEDs you must be pressing the combinations while connecting the control board to the power supply LED 1 Button with Button LED 2 Button SET with...

Страница 9: ...ND GND 24V 12 EN CONNECTION OF PUSH LOCK WITH MDL1805 MODULE Operation Whenever an impulse lock is used the MDL1805 module must be placed With this module whenever the automation receives an opening o...

Страница 10: ...current Power Supply 230Vac 50Hz Potency 65W 100W Door Type Opening to the right or left Internal or external opening Opening angle 90 Opening speed 90 Adjustable Closing speed 90 Adjustable Pause tim...

Страница 11: ...0 120 120 113 107 102 97 93 110 120 120 120 114 109 103 99 94 91 120 120 120 120 115 110 104 100 96 92 130 120 120 120 116 111 106 101 97 93 140 120 120 120 120 112 106 102 98 94 90 150 120 120 120 12...

Страница 12: ...nd make the markings Drill holes in the marked places Apply bushings in the holes made Direct the motor body and apply the screws tightening completely Fit the arm onto the shaft and tighten the corre...

Страница 13: ...Closes to memorize position and stays in normal operation after this cycle is completed Before connecting the automation to the current the stop must be installed so that the control board can recogn...

Страница 14: ...istance on door opening 1 to 32 Door slowdown speed 1 to 32 Closing speed 1 to 32 Closing deceleration distance 1 to 32 Closed automation force 1 to 32 Pause time 1 to 20 20 corresponds to 10 seconds...

Страница 15: ...ified MOTORLINE technician 1 Open the control board and check if it has a 230V power supply 2 Check the control board input A SAFETY SYSTEMS Opening security systems NO Closing security systems NO 1 D...

Отзывы: