13A
13B
60mm
167mm
47mm
EN
EN
06. THE CONTROL BOARD
TECHNICAL CHARACTERISTICS
06. THE CONTROL BOARD
TECHNICAL CHARACTERISTICS
Conet
or
es
1 •
+24V battery power input
2 •
Magnetic lock or impulse lock module
3 •
+12V auxiliary power supply
4 •
GND
5 •
+24V component power supply
6 •
GND
7 •
Opening safety photocells (NO)
8 •
2nd radar input
9 •
Two door interlock entry - Interlock
10 •
Double Door Lock Output - Interlock
11 •
Backup Power Function Selection
12 •
Double common - for 2-sheet system
13 •
Dual output - for 2-sheet system
14 •
Double entry - for 2-sheet system
15 •
1st radar entry
16 •
Safety photocells in the closing (NO)
17 •
FUTURE USE
18 •
FUTURE USE
19 •
FUTURE USE
20 •
FUTURE USE
21 •
FUTURE USE
22 •
FUTURE USE
PROGRAMMING
Turn on the electrical current. The door will work as follows:
Opens slowly → Closes (to memorize position) and stays in normal operation after this cycle is completed.
•
Before connecting the automation to the current, the stop must be installed, so that the
control board can recognize the course.
-
Decrease button
+
Increase button
SET
Select function button
TEST
Test button (START)
Dippers
ON
OFF
A
Left opening
Right opening
B
Second sensor switch
sensor and secondary induction
selection switch.
With this option, an order occurs on radar 1
and radar 2 at the same time.
Second sensor switch disabled
C
Disable lock
Activates 2/4 output for lock
LED1
For 2-leaf system - ON sets sheet 1
LED
Signal light - sensor signal indicator
LED2
Signals 2-leaf system active
To activate LED1 and LED2 functions:
01 •
Turn off power supply
02 •
Press "+" and "-" simultaneously and turn on the power
03 •
LED 1 will light up and the door starts recognizing
01 •
Turn off power
02 •
Press "+" and "SET" simultaneously and turn on power
03 •
LED 2 will light up and door recognition starts