IN-LOC OU-LOC GND 24+

1

2 3 4 5 6

OUT 12+

GND

GND

24V+

12+

EN

CONNECTION OF PUSH LOCK WITH MDL1805 MODULE

Operation: 

Whenever an impulse lock is used, the MDL1805 module must be placed.

With this module, whenever the automation receives an opening order, a signal is 

sent to the electrolock for 300ms to unlock and allow opening.

02. CONNECTION SCHEMES

Содержание M1805-X

Страница 1: ...V1 0 REV 10 2021 M1805 X M1805 X EN USER INSTALLER MANUAL...

Страница 2: ...This marking on the product or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should not be disposed of as other household wast...

Страница 3: ...enced in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid 01 SAFETY INSTRUCTIONS t...

Страница 4: ...utomatism turn off the power and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resett...

Страница 5: ...D 24 1 2 3 4 5 6 1 2 3 4 5 6 7 RAP5M PRO EN 02 CONNECTION SCHEMES COMPONENTS CONNECTION 2 M1601 Radar Control board Magnetic lock Electric lock MDL1805 module Battery 24V Automatism Radar 12V 12V The...

Страница 6: ...18 19 20 21 22 1 2 3 4 5 6 7 8 9 10 11 EN 02 CONNECTION SCHEMES RADARS AND PROGRAM SELECTOR CONNECTION PROGRAM SELECTOR EXTERNAL Radar M1601 INTERNAL Radar M1601 red white purple orange green green w...

Страница 7: ...gular doors with interlocking connected to each other you should be aware these connections Only when one of the doors is closed the other can open When using this function if one of the doors is disc...

Страница 8: ...Combination to turn on LED s To turn on off any of the LEDs you must be pressing the combinations while connecting the control board to the power supply LED 1 Button with Button LED 2 Button SET with...

Страница 9: ...ND GND 24V 12 EN CONNECTION OF PUSH LOCK WITH MDL1805 MODULE Operation Whenever an impulse lock is used the MDL1805 module must be placed With this module whenever the automation receives an opening o...

Страница 10: ...current Power Supply 230Vac 50Hz Potency 65W 100W Door Type Opening to the right or left Internal or external opening Opening angle 90 Opening speed 90 Adjustable Closing speed 90 Adjustable Pause tim...

Страница 11: ...0 120 120 113 107 102 97 93 110 120 120 120 114 109 103 99 94 91 120 120 120 120 115 110 104 100 96 92 130 120 120 120 116 111 106 101 97 93 140 120 120 120 120 112 106 102 98 94 90 150 120 120 120 12...

Страница 12: ...nd make the markings Drill holes in the marked places Apply bushings in the holes made Direct the motor body and apply the screws tightening completely Fit the arm onto the shaft and tighten the corre...

Страница 13: ...Closes to memorize position and stays in normal operation after this cycle is completed Before connecting the automation to the current the stop must be installed so that the control board can recogn...

Страница 14: ...istance on door opening 1 to 32 Door slowdown speed 1 to 32 Closing speed 1 to 32 Closing deceleration distance 1 to 32 Closed automation force 1 to 32 Pause time 1 to 20 20 corresponds to 10 seconds...

Страница 15: ...ified MOTORLINE technician 1 Open the control board and check if it has a 230V power supply 2 Check the control board input A SAFETY SYSTEMS Opening security systems NO Closing security systems NO 1 D...