![Mosa GE 6000 SX/GS Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/mosa/ge-6000-sx-gs/ge-6000-sx-gs_user-manual_1836892059.webp)
GE 6000 SX/GS
GE 6500 SX/GS
© MOSA
REV.
1
-0
9
/0
6
M
51
Technical data and machine description
The generating set GE 6000 / 6500 is a unit which transforms the mechanical energy, generated by endothermic engine, into
electric energy, through an alternator.
Is meant for industrial and professional use, powered by an endothermic engine; it is composed of various main parts such as:
engine, alternator, electric and electronic controls, the fairing or a protective structure.
The assembling is made on a steel structure, on which are provided elastic support which must damp the vibrations and also
eliminate sounds which would produce noise.
Technical data
GE 6000 SX/GS
GE 6500 SX/GS
A.C. GENERATOR
Three-phase generation
-
6.5 kVA (5.2 kW) / 400 V / 9.4 A
Single-phase generation
6 kVA (5.4 kW) / 230 V / 26 A
4 kVA / 230 V / 17.4 A
Single-phase generation
6 kVA (5.4 kW) / 110 V / 54.5 A
-
Frequency
50 Hz
50 Hz
Power factor (cos
ϕϕϕϕϕ
)
0.9
0.8
ALTERNATOR
self-excited, self-regulated, brushless
self-excited, self-regulated, with brush
Type
Single-phase, synchronous
Three-phase, synchronous
Insulating class
H
H
ENGINE
Mark
YANMAR
Model
L 100 AE
Type
4-Stroke
Displacement
406 cm
3
Cylinders
1
Output
6.5 kW (8.8 HP)
Speed
3000 rpm
Fuel consumption
245 g/kWh
Cooling system
Air
Engine oil capacity
1.6 l
Starter
Electric
Fuel
Diesel
GENERAL SPECIFICATIONS
Battery
12V -
38
Ah
Fuel tank capacity
23 l
Running time
17.5 h
Protection
IP 23
Dimensions max. Lxwxh *
1020x645x930
Weight (dry) *
194 Kg
200Kg
Noise level
94 LWA (69 dB(A) - 7 m)
92 LWA (67 dB(A) - 7 m)
* Dimensions and weight are inclusive of all parts.
21/10/04 35640GB
OUTPUT
Declared powers at the following ambient conditions: temperature 20*C, relative humidity 30% altitude 100 m above sea level.
In an
approximative
way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
For possible modifications or changes to be brought on the engines, with climate conditions different from those above
mentioned, please call our Assistance Authorized Centers.
ACOUSTIC POWER LEVEL
The machine respects the noise limits, expressed in sound power, given in the a.m. directives.
These limits can be used to judge the sound level produced on site.
For example: the sound power level of 100 LWA.
The sound pressure (noise produced) at 7 meters distance is about 75dBA (the limit value less 25).
To calculate the sound level at other distances use this formula:
dBAx = dBAy + 10 log
At 4 meters the noise level becomes: 75 dBA + 10 log = 80 dBA
ry²
rx²
7²
4²
Содержание GE 6000 SX/GS
Страница 2: ......
Страница 30: ......
Страница 31: ...GE 6000 SX GS GE 6500 SX GS 356409003 GB 0 9 0 6 21 10 04 35640M00 preparato da UPT approvato da DITE ENGLISH...
Страница 32: ......
Страница 60: ......
Страница 61: ...GE 6000 SX GS GE 6500 SX GS 356409003 F 0 9 0 6 21 10 04 35640M00 preparato da UPT approvato da DITE FRANCAIS...
Страница 62: ......
Страница 90: ......
Страница 91: ...GE 6000 SX GS GE 6500 SX GS 356409003 E 0 9 0 6 21 10 04 35640M00 preparato da UPT approvato da DITE ESPA OL...
Страница 92: ......
Страница 119: ...GE 6000 SX GS GE 6500 SX GS 356409003 D 0 9 0 6 21 10 04 35640M00 preparato da UPT approvato da DITE DEUTSCH...
Страница 120: ......
Страница 148: ...M 56 MOSA 1 0 04 04 08 04 04 M56 DIMENSIONI DIMENSIONS SCHEMI ELETTRICI ELECTRICAL SYSTEM RICAMBI SPARE PARTS...
Страница 152: ...Schema elettrico Electric diagram Schemas electriques GE 6000 SX GS 230Mx2 vers M 61 2 21 10 04 35640I MOSA REV 1 09 06...
Страница 164: ......
Страница 166: ......