![Mosa GE 6000 SX/GS Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/mosa/ge-6000-sx-gs/ge-6000-sx-gs_user-manual_1836892053.webp)
Troubleshooting
M
40.2
© MOSA
REV.3-07/06
28/01/03 M40I_1500G_GE
GE
Diesel engine
The motor does not start
up
1) Start-up switch (I6) (where it is
assembled) in incorrect position
2) Emergency button (L5) pressed
3) Preheating (where it is assembled)
4) Engine control unit or starting key
faulty.
5) Battery low
6) Battery cable terminals loose or
corroded
7) Start-up motor defective
8) No fuel or air in feed circuit
9) Malfunction on feed circuit: defective
pump, injector blocked, etc.
10) Air filter or fuel filter clogged
11) Air in the gasoil filter.
12) Motor stopping device defective
13) Malfunction on electrical power circuit
on generator control panel
1) Check position
2) Unblock
3) Lacking or insufficient preheating
phase for sparkplugs.
Malfunction in circuit: repair.
4) Replace
5) Recharge or replace.
Check the battery charge circuit on
motor and automatic panel.
6) Tighten and clean. Replace if
corroded.
7) Repair or replace.
8) Refill tank, un-aerate the circuit.
9) Ask for intervention of Service
Department.
10) Clean or replace
11) Take the air out filling the filter with gasoil.
12) Replace.
13) Check and repair.
Problem
Possible cause
Solution
The motor does not
accelerate. Inconstant
speed.
1) Air filter or fuel filter clogged.
2) Malfunction on feed circuit: defective
pump, injector blocked, etc.
3) Oil level too high.
4) Motor speed regulator defective.
1) Clean or replace.
2) Ask for intervention of Service
Department.
3) Eliminate excess oil.
4) Ask for intervention of Service
Department
Black smoke
1) Air filter clogged.
2) Overload.
3) Injectors defective. Injection pump
requires calibration.
1) Clean or replace
2) Check the load connected and
diminish.
3) Ask for intervention of Service
Department.
White smoke
1) Oil level too high.
2) Motor cold or in prolonged operation
with little or no load.
3) Segments and/or cylinders worn out.
1) Eliminate excess oil.
2) Insert load only with motor sufficiently
hot
3) Ask for intervention of Service
Department.
Too little power provided
by motor.
1) Air filter clogged.
2) Insufficient fuel distribution, impurities
or water in feed circuit.
3) Injectors dirty or defective.
1) Clean or replace.
2) Check the feed circuit, clean and
refill once again.
3) Ask for intervention of Service
Department.
Low oil pressure
1) Oil level insufficient
2) Air filter clogged.
3) Oil pump defective.
4) Alarm malfunction.
1) Reset level. Check for leaks.
2) Replace filter.
3) Ask for intervention of Service
Department.
4) Check the sensor and electrical
circuit.
High temperature
1) Overload
2) Insufficient ventilation.
3) Insufficient coolant liquid (Only for
water cooled motors)
1) Check the load connected and
diminish.
2) Check the cooling vent and relative
transmission belts
3) Restore level. Check for leaks or
breakage in the entire cooling circuit,
pipes, couplings, etc.
ENGINE
Содержание GE 6000 SX/GS
Страница 2: ......
Страница 30: ......
Страница 31: ...GE 6000 SX GS GE 6500 SX GS 356409003 GB 0 9 0 6 21 10 04 35640M00 preparato da UPT approvato da DITE ENGLISH...
Страница 32: ......
Страница 60: ......
Страница 61: ...GE 6000 SX GS GE 6500 SX GS 356409003 F 0 9 0 6 21 10 04 35640M00 preparato da UPT approvato da DITE FRANCAIS...
Страница 62: ......
Страница 90: ......
Страница 91: ...GE 6000 SX GS GE 6500 SX GS 356409003 E 0 9 0 6 21 10 04 35640M00 preparato da UPT approvato da DITE ESPA OL...
Страница 92: ......
Страница 119: ...GE 6000 SX GS GE 6500 SX GS 356409003 D 0 9 0 6 21 10 04 35640M00 preparato da UPT approvato da DITE DEUTSCH...
Страница 120: ......
Страница 148: ...M 56 MOSA 1 0 04 04 08 04 04 M56 DIMENSIONI DIMENSIONS SCHEMI ELETTRICI ELECTRICAL SYSTEM RICAMBI SPARE PARTS...
Страница 152: ...Schema elettrico Electric diagram Schemas electriques GE 6000 SX GS 230Mx2 vers M 61 2 21 10 04 35640I MOSA REV 1 09 06...
Страница 164: ......
Страница 166: ......