Clearing the Overtravel Limits and Fault Bits
Clearing the Overtravel Limits and Fault Bits
To disable (clear) the overtravel limits, enter EIGN(2) and EIGN(3) in the SMI software Ter-
minal window. This sets I/O 2 (positive overtravel limit) and I/O 3 (negative overtravel limit)
as general inputs/outputs instead of being used as travel limits. To set all status bits in Word 0
as general inputs/outputs, enter EIGN(W,0).
NOTE:
You can either type the command in the white text box or type the com-
mand directly in the blue area of the terminal screen and then click Send or press
Enter.
The active and asserted bits are cleared, as shown in the following figures.
EIGN Command Entered
Active and Asserted Bits Cleared
To clear the historical fault bits, enter ZS. All remaining fault bits are cleared, as shown in the
following figures.
ZS Command Entered
Remaining Bits Cleared