Page 11
L38DF-ST See-thru Indoor Gas Fireplace
Part No. XG0810 - 092109
f i r e f e a t u r e
Figure 17b.
Vertical venting with 2 offsets (1 offset= two 90° bends).
Installation
Figure 18.
Reducing Vertical Vent from 5/8" to 4/7".
Reduced Vertical Installation
(Available with Linear LDVPV47 Power Vent
ONLY)
It is possible to reduce vertical vent runs from 5"/8" venting to 4"/7"
venting. Reduced vertical venting may only be used when the Linear
(In-line) Power Vent is required. This is commonly due to longer than
normal vent runs, or unusually long horizontal Vent runs.
Installing The Horizontal &
Vertical Exterior Power Vent
A Power Vent is required where the Termination is located too far
away from the gas fireplace and/or
if the vent run is beyond the scope
of this document, or the specifications recommend vent augmenta
-
tion. There are four 4/7 Power Vent models available. These Power
Vents are required for Superior venting, safe operation & years of
trouble free operation.
The available Montigo Power Vent models are:
LDVPV47 (Linear, Interior In-line Power Vent,
document, XG0700)
.
EDVPV47 (External Power Vent Module,
document, XG0750)
.
EDVRSPV47 (Exterior
Vertical
Roof mount 4/7 stainless steel Power
Vent system,
document, XG1303)
EDVWSPV47 (Exterior
Horizontal
Wall mount 4/7 stainless steel Power
Vent system,
document, XG1302)
.
Figure 24.
Combustible mantles and facings, (Both Sides Typical).
Horizontal Run (in)
Fireplace Facing
When selecting the finish material for your fireplace, it is important to
remember the following:
THE OPENING MUST NOT BE OBSTRUCTED
IN ANY WAY - to do so restricts the air supply for the control
compartments and heat exchanger it also prevents access for
servicing controls.
The face of the fireplace may be painted to match the room decor,
provided you use a heat-resistant paint. Decorative facing must not
extend past the fireplace opening at all, because it will interfere with
the access to retainers for removal of glass door.
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the
top and on the front of the fireplace provided that they do not project
beyond shaded area shown in
Figure 24
. Side wall clearances are 3".
Combustible surrounds may be installed with 3" clearance to the side
of the fireplace as shown in
Figure 25
.
Non-Combustible
Facing Material
Steel Stud construction
allowable within this area
Top of
fireplace