L38DF-ST See-thru Indoor Gas Fireplace

Part No. XG0810 - 092109

f i r e    f e a t u r e 

Introduction

Thank You

 for choosing a Montigo Gas Fireplace.

About this Fireplace:

The 

L38DF-ST (

See-thru)

 is a fireplace with a linear-style burner. This 

fireplace can be converted to both a Top Vent or Rear Vent application, 

and is available in the models below.

The 

L38DF-ST

 (See-thru) is rated for Natural Gas or

 

Propane at 27,000 

BTU/H (7.91 Kilowatts) Input. 

►   L38DF-ST;

 Top Vent, Millivolt Pilot.

►   L38DF-ST-F;

 Top and Rear Vent, SIT (IPI Electronic)

This manual covers installation, operation and maintenance. Lighting, 

operation and care of this fireplace can be easily performed by the 

homeowner.  However,  all  installation  and  service  work  should  be 

performed by a qualified or licensed installer, plumber, or gas fitter who 

is qualified or licensed by the state, province, region, or governing body 

in which the appliance is being installed.

This  manual  covers  all  models  and  unless  otherwise  specified,  the 

designation 

L38DF-ST

  refers  to  all  variations  of  the  model  above. 

Sections which are specific to a particular variation are marked with a 

 symbol, plus the appropriate model number.

Warranty and Installation Information:

The Montigo warranty will be voided by, and Montigo

 

disclaims any 

responsibility for, the following actions:

►      Modification  of  the  fireplace  and/or  components  including  Direct-Vent 

assembly or glass doors.

►     Use of any component part not manufactured or approved by Montigo in 

combination with this Montigo fireplace system.
►     Installation other than as instructed in this manual.

Consult your local Gas Inspection Branch on installation requirements 

for factory-built gas fireplaces. Installation & repairs should be done by 

a qualified contractor.
Installations in Canada

 must conform to the current 

CAN/CGA B-

149.1

 and 

.2

 Gas Installation Code and local regulations. If the optional 

air-circulating  fan  kit  is  installed,  it  must  be  electrically  grounded  in 

accordance with 

CSA C22.1

 Canadian Electrical Code Part 1 and/or 

Local Codes.

Installations in the USA

 must conform to local codes, or in the absence 

of local codes to the National Fuel Gas Code, 

ANSI Z223.1-1988

. If the 

optional air-circulating fan is installed, it must be grounded in accordance 

with local codes or, in the absence of local codes, with the National 

Electrical Code, 

ANSI/NFPA 70-1987. 

Within the

 State of Massachusetts 

this fireplace must comply with 

NFPA-54 Chapter 10

.

     CAUTION!

Due  to  its  high  operating  temperatures,  the  appliance 
should  be located out of traffic & away from furniture and 
draperies.

  Children and adults should be alerted to the hazards 

of the high surface temperature, which could cause 
burns or clothing ignition.

  Young children should be carefully supervised when 

they are in the same room as the appliance.

  Clothing or other flammable materials should not be 

placed on or near the appliance.

WARNING!

When this appliance is installed directly on carpeting, tile or any 

combustible material other than wood flooring, it must be installed 

on a metal or wood panel extending the full width and depth of 

the appliance.

Содержание L38DF-ST series

Страница 1: ...enancecancause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Warning What to do if you smell...

Страница 2: ...gas fireplace will give you years of durable reliable use Welcome to the FireFeature family of gas fireplace products Safety Alert Key DANGER Indicates a hazardous situation which if not avoided will...

Страница 3: ...manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult your local Gas Inspection Branch on installation requ...

Страница 4: ...e to unprotected combustible walls which are perpendicular to the fireplace opening must not project beyond the shaded area shown in Figure 24 For protection against freezing temperatures it is recomm...

Страница 5: ...lation This section covers the installation of direct venting and terminations Installation Requirements Q Q L38DF ST model fireplaces are certified for use with Montigo Standard Series 5 8 venting co...

Страница 6: ...the top of the termination where temperatures are highest 2 Attach to the faceplate of the termination using four sheet metal screws 3 IfinstallingtheterminationoverVinylsiding UsetheVSSTermination s...

Страница 7: ...its set by the venting graph see Figure 7 Figure 8 Retracted Installation using a combination of solid and flex venting Use the vent graph to determine your allowable run then select appropriate compo...

Страница 8: ...tics will change if the maximum vent height is used Minimum clearances 2 from vent to all combustible materials must be maintained Amaximum of two offsets each offset has two 90 bends may be made and...

Страница 9: ...tallation CAUTION The Installation shown in Figure 12 only 5 8 PEXT Vent to be used Power Vent models LDVPV47 EDVRSPV58 and EDVWSPV58 to be used within the shaded area of graph See Index of this guide...

Страница 10: ...ions may be used in conjunction with one another to obtain different possible horizontal length instal lations NOTE Flex section must not exceed maximum horizontal length of 3 feet and for this applic...

Страница 11: ...Power Vent Module document XG0750 EDVRSPV47 Exterior Vertical Roof mount 4 7 stainless steel Power Vent system document XG1303 EDVWSPV47 Exterior Horizontal Wall mount 4 7 stainless steel Power Vent s...

Страница 12: ...valent Figure 27a Wiring schematic for optional fans G L2 WH L1 BLK p g Quick Connect lu to motor WARNING We recommend careful consideration be given to the effects of elevated mantel temperatures whi...

Страница 13: ...aintenance or cleaning Install in reverse order Installed Gas Valve Cover Finger Holes Remove the Horizontal Access Panel To install the door hook the top edge of the door frame into place Lower thedo...

Страница 14: ...ure 29b Spreading designer beads evenly Propane L38DF ST fireplace have the option of installing the optional cultured rocks or designer glass beads As described below Propane gas the designer beads o...

Страница 15: ...ollow the gas supplier s instructions To Turn Off Gas To Appliance 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Replace the lower Horizontal access panel 1 Turn off rem...

Страница 16: ...Page 16 L38DF ST See thru Indoor Gas Fireplace Part No XG0810 092109 f i r e f e a t u r e Operation...

Страница 17: ...Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instru...

Страница 18: ...nob marked Hi Lo in the centre of the gas control valve See Figure 32 The front burners are not adjustable Q Q To raise the flame height turn the black knob located behind the lower trim counter clock...

Страница 19: ...until the bubbling stops completely Figure 34 Pilot Burner Troubleshooting The following is a troubleshooting chart of possible problems PROBLEM CORRECTIVE ACTION Noisy Pilot Flame Locate pilot adjus...

Страница 20: ...1152 Oriface LPG Oriface NG L38DF ST I RGC1004 RGC1003 RPA003 RPA004 ROR1151 ROR1152 RDTL38 L38DF ST A RGC3033 RGC3034 RPA052 RPA053 ROR1151 ROR1152 RDTL38 Troubleshooting Follow this information to r...

Страница 21: ...ust be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance wi...

Страница 22: ...tlet 3 feet minimum in the United States 6 feet 1 8 m minimum in Canada L clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm mi...

Страница 23: ...above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in si...

Страница 24: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0810 092109 f i r e f e a t u r e...

Отзывы: