Page 15

L38DF-ST See-thru Indoor Gas Fireplace

Part No. XG0810 - 092109

f i r e    f e a t u r e 

Operation - Model L38DF-ST

L38DF-ST

with Continuous  Pilot

WARNING:

 

If you do not follow these instructions exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.

 

Q

If  you  cannot  reach  your  gas  supplier,  call  the  Fire 
Department.

C.  Use only your hand to push in or turn the gas control knob. 

Never use tools. If  the knob will not push in or turn by hand, 
don't try to repair it, call a qualified service technician. Force 
or attempt to repair may result in a fire or explosion.

D.  Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system, and 
any gas control which has been under water.

A.  This appliance has a pilot which must be lighted by hand. 

When lighting the pilot, follow these instructions exactly.

B.  BEFORE LIGHTING smell all around the appliance area for 

gas.  Be sure to smell next to the floor because some gas is 
heavier than air and will settle on the floor.

  What To Do If You Smell Gas:

 

Q

Do not try to light any appliance.

 

Q

Do not touch any electrical switch; do not use any phone 
in your building.

 

Q

Immediately call your gas supplier from a neighbour's 
phone. Follow the gas supplier's instructions.

To Turn Off Gas To Appliance:

3.  Push in gas control knob slightly and turn  

  clockwise to 

"Off".  Do not force.

4.  Replace the lower Horizontal access panel.

1.  Turn off remote switch.
2.  Lift out the lower Horizontal access panel.

1.  STOP!  Read the safety information above on this label.
2.  Lift out the lower Horizontal access panel.
3.  Push in gas control knob and turn clockwise 

  to "OFF."

4.  Wait  five  (5)  minutes  to  clear  out  any  gas.  Smell  for  gas, 

including near the floor. If you then smell gas, STOP! Follow 
"B" in the safety information above on this label. If you don't 
smell gas, go to the next step.

5.  Locate pilot burner 

(See illustration at right.)

 and follow steps 

below.

6.  Turn  knob  on  gas  control  counter  clockwise   

    to 

"PILOT."

7.  Push in gas control knob completely and hold. Light with Piezo 

Igniter button. Continue to hold the control knob in for about 
(1) minute after the pilot is lit. Release the knob and it will pop 
back up. Pilot should remain lit. If it goes out repeat steps 3 
through 8.

 

Q

If  knob  does  not  pop  up  when  released.  Stop  and 
immediately  call  your  service  technician  or  gas 
supplier.

 

Q

If the pilot will not stay lit after several tries, turn the gas 
control knob to "OFF" and call your service technician 
or gas supplier.

8.  Push  in  gas  control  knob  and  turn 

counter-clockwise  

  to "ON."

9.  Replacethe  lower  Horizontal  access 

panel.

Lighting  Instructions:

For Your Safety - READ BEFORE LIGHTING:

NOTE: 

Gas control knob cannot be turned from 

"PILOT" to "OFF" unless knob is pushed

 

 in slightly.  Do not force.

Содержание L38DF-ST series

Страница 1: ...enancecancause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Warning What to do if you smell...

Страница 2: ...gas fireplace will give you years of durable reliable use Welcome to the FireFeature family of gas fireplace products Safety Alert Key DANGER Indicates a hazardous situation which if not avoided will...

Страница 3: ...manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult your local Gas Inspection Branch on installation requ...

Страница 4: ...e to unprotected combustible walls which are perpendicular to the fireplace opening must not project beyond the shaded area shown in Figure 24 For protection against freezing temperatures it is recomm...

Страница 5: ...lation This section covers the installation of direct venting and terminations Installation Requirements Q Q L38DF ST model fireplaces are certified for use with Montigo Standard Series 5 8 venting co...

Страница 6: ...the top of the termination where temperatures are highest 2 Attach to the faceplate of the termination using four sheet metal screws 3 IfinstallingtheterminationoverVinylsiding UsetheVSSTermination s...

Страница 7: ...its set by the venting graph see Figure 7 Figure 8 Retracted Installation using a combination of solid and flex venting Use the vent graph to determine your allowable run then select appropriate compo...

Страница 8: ...tics will change if the maximum vent height is used Minimum clearances 2 from vent to all combustible materials must be maintained Amaximum of two offsets each offset has two 90 bends may be made and...

Страница 9: ...tallation CAUTION The Installation shown in Figure 12 only 5 8 PEXT Vent to be used Power Vent models LDVPV47 EDVRSPV58 and EDVWSPV58 to be used within the shaded area of graph See Index of this guide...

Страница 10: ...ions may be used in conjunction with one another to obtain different possible horizontal length instal lations NOTE Flex section must not exceed maximum horizontal length of 3 feet and for this applic...

Страница 11: ...Power Vent Module document XG0750 EDVRSPV47 Exterior Vertical Roof mount 4 7 stainless steel Power Vent system document XG1303 EDVWSPV47 Exterior Horizontal Wall mount 4 7 stainless steel Power Vent s...

Страница 12: ...valent Figure 27a Wiring schematic for optional fans G L2 WH L1 BLK p g Quick Connect lu to motor WARNING We recommend careful consideration be given to the effects of elevated mantel temperatures whi...

Страница 13: ...aintenance or cleaning Install in reverse order Installed Gas Valve Cover Finger Holes Remove the Horizontal Access Panel To install the door hook the top edge of the door frame into place Lower thedo...

Страница 14: ...ure 29b Spreading designer beads evenly Propane L38DF ST fireplace have the option of installing the optional cultured rocks or designer glass beads As described below Propane gas the designer beads o...

Страница 15: ...ollow the gas supplier s instructions To Turn Off Gas To Appliance 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Replace the lower Horizontal access panel 1 Turn off rem...

Страница 16: ...Page 16 L38DF ST See thru Indoor Gas Fireplace Part No XG0810 092109 f i r e f e a t u r e Operation...

Страница 17: ...Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instru...

Страница 18: ...nob marked Hi Lo in the centre of the gas control valve See Figure 32 The front burners are not adjustable Q Q To raise the flame height turn the black knob located behind the lower trim counter clock...

Страница 19: ...until the bubbling stops completely Figure 34 Pilot Burner Troubleshooting The following is a troubleshooting chart of possible problems PROBLEM CORRECTIVE ACTION Noisy Pilot Flame Locate pilot adjus...

Страница 20: ...1152 Oriface LPG Oriface NG L38DF ST I RGC1004 RGC1003 RPA003 RPA004 ROR1151 ROR1152 RDTL38 L38DF ST A RGC3033 RGC3034 RPA052 RPA053 ROR1151 ROR1152 RDTL38 Troubleshooting Follow this information to r...

Страница 21: ...ust be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance wi...

Страница 22: ...tlet 3 feet minimum in the United States 6 feet 1 8 m minimum in Canada L clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 16 inches 41 cm mi...

Страница 23: ...above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in si...

Страница 24: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0810 092109 f i r e f e a t u r e...