![background image](http://html1.mh-extra.com/html/montague/136w36/136w36_instruction-manual_1829509023.webp)
SERVICE
Burner Pilot Assembly
(Figure 20)
7. Remove the orifice hex nut fitting from the
venturi.
8. Remove the orifice from the hex nut fitting.
9. Reassemble by reversing procedure.
WARNING
ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH A SOAP AND
WATER SOLUTION (BUBBLES). DO NOT
USE AN OPEN FLAME.
Orifice Assembly
(Figure 21)
BURNER VALVE
The burner valves are located on the manifold
behind the control panel cover.
CAUTION
TURN OFF THE GAS SUPPLY AT THE
MANUAL SHUTOFF VALVE THAT IS NEXT
TO THE BROILER BEFORE ATTEMPTING
TO LOOSEN ANY GAS CONNECTIONS.
1. Remove the control panel cover as
described under Covers & Panels to
access the burner valve.
2. Disconnect the gas line from the back of
the burner valve.
3. Unscrew the burner valve from the
manifold.
4. Install the new burner valve.
NOTE:
Make sure that the pipe joint
compound or pipe thread sealant that is being
used is resistant to the corrosive actions of
liquefied petroleum gases.
5. Connect the gas line to the back of the
valve.
6. Turn the main gas shutoff valve to the
broiler to the “ON” position.
WARNING
ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH A SOAP AND
WATER SOLUTION (BUBBLES). DO NOT
USE AN OPEN FLAME.
7. Light pilot.
8. Reinstall the control panel cover and
control valve knobs.
9. Turn burner valve full on and check that
burner is properly lit.
21
1
Set Screw
2
Gas Input
3
Gasket
4
Venturi
5
Lock Nut
6
Bracket
1
Orifice
2
Orifice Hex Fitting
3
Bracket
1
2
3