INSTALLATION
NOTE:
Pilots should be lit and properly
adjusted before adjusting the main burners.
1. Lift off the manifold cover to access the air
shutter for each main burner.
2. Turn main burner control valve on fully,
(counterclockwise) in order to adjust
burner flame.
3. Increase the air shutter openings until the
flame on the burner begins to “lift”. Then
close shutter until flame no longer floats,
and lock in place. A yellow streaming flame
indicates insufficient air. Correct this
condition by increasing air shutter opening.
Main Burner Venturi w/ air mixer
(Figure 10)
4. After all main burners are properly
adjusted, reinstall the manifold cover.
5. Turn all main burner control valves fully
clockwise to turn the main burners off.