SERVICE
1. Remove the control panel cover as
described under
Covers and Panels
to
access the pilot valve.
2. Disconnect the gas line from the back of
the valve.
3. Unscrew the pilot valve from the manifold.
4. Install the new pilot valve with the
adjustment screw facing the front of the
broiler.
NOTE:
Make sure that the pipe joint
compound or pipe thread sealant that is being
used is resistant to the corrosive actions of
liquefied petroleum gases.
5. Connect the gas line to the back of the
valve.
6. Turn the main gas shutoff valve to broiler
to the “ON” position.
WARNING
ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH A SOAP AND
WATER SOLUTION (BUBBLES). DO NOT
USE AN OPEN FLAME.
7. Light pilot and adjust pilot valve.
8. Reinstall control panel cover and control
valve knobs.
Pilot Valve
(Figure 17)
PILOT ASSEMBLY AND ORIFICE
The pilot assembly is located adjacent to each
burner. The connection for the pilot assembly
is accessed by removing the venturi cover.
1. Remove the venturi cover as described in
Covers and Panels
.
2. Disconnect gas line from back of pilot
assembly.
3. Unscrew the two screws securing the pilot
assembly and pilot assembly bracket.
NOTE:
Check condition of the pilot orifice and
replace if damaged.
4. Install the new pilot assembly, orifice and
pilot assembly bracket.
5. Connect the gas line to the back of the
pilot assembly.
NOTE:
Make sure that the pipe joint
compound or pipe thread sealant that is being
used is resistant to the corrosive actions of
liquefied petroleum gases.
6. Turn the main gas shutoff valve to the
broiler to the “ON” position.
WARNING
ALL GAS JOINTS DISTURBED DURING
SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH A SOAP AND
WATER SOLUTION (BUBBLES). DO NOT
USE AN OPEN FLAME.
19
1
Manifold
2
Gas Line
3
Pilot Valve
1
2
3
Содержание 136W36'
Страница 31: ...EXPLODED VIEW 29 C36 C45 ...
Страница 33: ...EXPLODED VIEW 31 36W36 43W36 ...