INSTALLATION
Gas Pressure Tap
(Figure 6)
PILOT INITIAL ADJUSTMENT
Each burner has a separate pilot burner. The
pilot flame is adjusted through access holes in
the valve control panel, Figure 7. Pilot access
is through the broiler panel opening.
Pilot Valves
(Figure 7)
1. Turn the main gas shutoff valve to the on
position.
NOTE:
Pilots are on at all times if main shutoff
valve is in the on position and pilot adjustment
valves are open.
2. Light each pilot.
3. Adjust pilot valve adjustment screw so that
each pilot burner has a steady blue flame,
Figure 8.
Pilot Burner
(Figure 8)
Pilot Value
(Figure 9)
BURNER ADJUSTMENT
The efficiency of the broiler depends on a
delicate balance between the supply of air and
the volume of gas at each main burner
resulting in complete combustion. Whenever
this balance is disturbed, poor operating
characteristics occur. An air shutter, Figure 9,
on the front of each main burner controls the
air supply.