manualshive.com logo in svg
background image

Fine Cooking Equipment For Over 70 Years

1. Preparation For Installation:

Z223.1

Installation must be made by a licensed plumber.

Safe and satisfactory operation of the broiler depends, to a great extent,

upon it’s proper installation. It should be installed in accordance with the National Fuel Gas Code

, these instructions, and applicable State and Local Codes.

A gas pressure regulator is supplied with your broiler. The regulator must be installed before
connecting broiler to gas supply line.

The broiler and it’s individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 kPa).

The broiler must be isolated from the gas supply piping system by closing it’s individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than 1/2 psig (3.45 kPa).

For radiant-type broilers, radiant tabs drop into holes in the firebox. For lava rock-type broilers, lava
rock grates rest on front and rear support surface of the firebox. Disburse lava rock evenly in one layer
ONLY throughout the firebox area, leaving air spaces. For both types, top grates are notched to secure
grate to lip of firebox gutter.

Please note: air vent can plug with grease, thereby shutting gas

supply off. Install regulator in a drip-free area.

RLRB-A BUDGET SERIES CHAR BROILERS

For Your Safety

Warning!

Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death.
Read the installation, operation and maintenance
instructions thoroughly before installing or servicing this
equipment.

To Purchaser

After installation of your broiler, immediately contact your local gas supplier to obtain information
in the event the user of your equipment smells gas. This information must be posted in a
prominent location.

To User

Upon receipt of this broiler, inspect it thoroughly for any damage which may have occurred
during shipment. If damage is observed, contact the delivery agency immediately.

RETAIN THIS MANUAL FOR FUTURE USE

Installation,

Operation &

Maintenance

Instructions

Do NOT store or use gasoline or
other flammable vapors and liquids
in the vicinity of this, or any other
equipment.

The Connerton Company

1131 E. Wakeham Avenue, Santa Ana, CA 92705-4145

Telephone: (714) 547-9218   Fax: (714) 547-1969

www.connertoncompany.com

Содержание RLRB-A

Страница 1: ...e lava rock evenly in one layer ONLY throughout the firebox area leaving air spaces For both types top grates are notched to secure grate to lip of firebox gutter Please note air vent can plug with grease thereby shutting gas supply off Install regulator in a drip free area RLRB A BUDGET SERIES CHAR BROILERS For Your Safety Warning Improper installation adjustment alteration service or maintenance...

Страница 2: ...broiler to the gas supply line Under no circumstances should the gas supply line be smaller than the inlet pipe on the broiler A gas shutoff valve must be installed in the gas supply line upstream of the broiler for complete shutdown and service Use pipe sealant on all pipe joints Sealant must be resistant to the action of L P gasses For proper performance the broiler must be level If legs are pro...

Страница 3: ...3 00 225 00 Pilot Valve 6 60 100 01 Top Grate 14 00 250 00 Manual Control Valve 7 60 150 00 Burner 15 00 500 00 Chrome Knob 60 200 02 Orifice Hood Propane 00 275 02 Regulator Propane 17 00 175 00 Lava Rock IMPORTANT Lava Rock NOT to be used with Radiants 10 16 00 275 01 Regulator Natural 8 60 200 01 Orifice Hood Natural For part numbers ending in xx specify model size ie 65 400 37 for a RLRB 23 37...

Страница 4: ...t manufactured is free from defects in material or workmanship Our obligation under this warranty shall be limited to furnishing without charge any part of said product which upon examination by The Connerton Company shall prove to be defective Parts wear is not considered a defect The Connerton Company will not be responsible for labor or transportation charges incidental to the replacement of sa...