Bulk Coin Recycler Technical Manual
TSP157.doc
Issue 1.3
– Jan 11
Money Controls 2008. All rights reserved.
Page 25 of 45
3.7 Electrical Interface Requirements
Table 8: Power Supply
Voltage:
+12V to +24V DC +/- 10%
Absolute:
Min +10V Max +27V
Min / Max rise time:
5ms / 500ms
(From 0V to within supply range)
Min / Max fall time:
5ms / 500ms
(From within supply range to 0V)
Acceptor Power up time:
200 ms from the application of a valid
voltage supply. A valid supply must be
between the limits specified above.
Ripple voltage [ < 120Hz ]:
< 1 Volt
Ripple voltage [ > 120Hz ]:
< 100mV
Ripple voltage [ > 1KHz ]:
< 20mV
Table 9: Current Consumption
Typical:
70mA
Maximum:
2.0A with sorter.
3.0A with sorter and active manifold.
3.8 Power-up Diagnostics
When the SR5i powers up, it performs an EEPROM self-check. If there is a problem with the
checksum, the LED will turn red and no coins will be accepted.
If diagnostic self check is
enabled
, the following are checked and if there is a problem then
the accept lines show the alarm code, for as long as the fault is present.
Blockage in the sensor area / faulty sensor (AM, FM, Piezo & Credit sensors).
The coin entry optics are checked for a blockage.
The sorter optics are checked for a blockage.
Note: If the sorter has been removed, then the SR5i will think the sorter optics are blocked and
therefore the alarm condition will be permanent. This can only be rectified by re-fitting a sorter.
When the blockage / fault is cleared, the alarm code will automatically be removed.