2.21 Fault Finding and Repair
Table 6: Fault Finding and Repair.
Problem:
Check:
Cure:
Coins fail to un-jam:
Ensure coin exit is clear.
Remove blockage from coin exit.
Ensure correct coins in hopper.
Fill hopper with correct coins.
Ensure no badly bent coins in
hopper.
Remove bent coin/s.
Motor fails to run:
Supply fuse.
Replace fuse.
Protection device tripped.
Wait 30 seconds with supply OFF.
Hopper has detected an opto fault.
Check EEPROM flags.
Over payout of coins: Check opto area/coin exit area for
dirt.
Clean opto/coin exit area.
Under
Payout
Of
Coins:
Check opto area/coin exit area for
dirt.
Clean opto/coin exit area.
Ensure hopper contains sufficient
coins.
Refill hopper.
2.22 Appendix A
2.22.1 CCTALK INTERFACE CIRCUIT
This is the
ccTalk
electronic interface circuit on SCH2.
There are many options for the host interface circuit but we recommend an open-collector
drive.
Figure 5:
ccTalk
Interface Circuit: