Bulk Coin Recycler Technical Manual
TSP157.doc
Issue 1.3
– Jan 11
Money Controls 2008. All rights reserved.
Page 15 of 45
a) Power lost during payout sequence
Counter
Initial value
Pay 3 from 10
then lose power
Last payout : coins paid
0
3
Last payout : coins unpaid
0
7
Hopper dispense count
0
3
Hopper life dispense count
N
N + 3
Coins remaining = 7
b)
‘Emergency stop’ command issued during payout sequence
Counter
Initial
value
Pay 3 from 10 then
‘Emergency stop’
Cycle power
off then on
‘Emergency stop’ return value
0
7
0
Last payout : coins paid
0
3
3
Last payout : coins unpaid
0
7
ZERO
Hopper dispense count
0
3
3
Hopper life dispense count
N
N + 3
N + 3
Coins remaining = 7
c)
‘Emergency stop’ command issued during payout sequence AND a coin is seen after the
hopper replies with unpaid coins.
Counter
Initial
value
Pay 3 from 10 then
‘Emergency stop’ +
late coin exit
Cycle power
off then on
‘Emergency stop’ return value
0
7
6
on retry
0
Last payout : coins paid
0
4
4
Last payout : coins unpaid
0
6
ZERO
Hopper dispense count
0
4
4
Hopper life dispense count
N
N + 3
N + 4
Coins remaining = 6
In this more complicated example, the hopper dispense count and the hopper life dispense
count end up with the correct values even though a coin was seen on the exit optos after the
motor stopped. For the host machine to find the correct value of unpaid coins it would need
to re-
send the ‘Emergency stop’ command or use the ‘Request hopper status’ command
before
power was lost - otherwise it would think there were 7 unpaid coins rather than 6.