P a g e | 13
3.4.3
Connecting the Fireplace
Connect to water and electrical sources using the
types of connections described below.
3.4.3.1
Water Connections
Cold Water Inlet Connection:
For the auto-fill
option, use the 12”-18” long, ¼” diameter poly tubing
stub-out that is packed in a plastic bag and taped to
the rear panel of the unit. It is recommended that
this tubing be joined to the water feed line by using a
John Guest, ¼”, quick connect union (supplied) as
shown in Figure 14.
It is also recommended that a compression fitting
with a shut-off valve be fitted at the water source (a
ball valve of the type shown in the Figure 15, not
supplied).
Note:
There is another water shut-off valve that is
accessible through the front of the fireplace under
the media panel.
Figure 13
Figure 14
(John Guest quick Conn., supplied)
Figure 15
(Ball valve w/Comp. fittings, not supplied)