3.6
Troubleshooting
Follow the procedures outlined below to diagnose and resolve problems.
Note:
Always remove
power from the system at the breaker box before replacing electrical components. To restart
the system, turn OFF the power at the beaker box for 30 seconds and then restore.
3.6.1
Fault Diagnosis Chart
PROBLEM
POSSIBLE CAUSE
CORRECTIVE ACTION
Flame and backlight are
not visible but fireplace
display shows it’s turned
on
Wiring is loose at fireplace
Shutoff the breaker at the
breaker panel and check the
connections
Breaker panel connection is
loose or breaker is defective
Shutoff the breaker, check the
breaker panel connections,
verify voltages, and
tighten/replace as needed.
Fireplace lights up but
there is no flame visible
Boiler connections are loose
Disconnect from power source
and inspect for loose
connections between the
boiler and its control board
Boiler control board is defective
Replace the control board with
one of the same model and
part #
Nothing comes on (front
panel screen, etc.)
There is a problem with the
keypad and/or its mounting that
is preventing the buttons from
functioning
Reposition the fireplace in the
installation so that no part of
the fireplace is interfering with
the keypad controls. Check
that there is no foreign
material lodged in the keypad
Power was “live” when the
fireplace was installed
Turn the main breaker to the
"OFF" position for 30 seconds.
Next flip the breaker back into
the "on" position for 20
seconds for a complete reboot
of control section.
Not operating the keypad
properly with finger
Press the end of your finger
firmly on the keypad and apply
moderate pressure
Loose connection on control
board
Check functions with remote
control. if functional, check
wiring connections on control
board
Fireplace turns off on its
own and will not come
Fault code 07 “BOILER OVER
TEMPERATURE” is shown on
the display
Refill boiler or repair water
supply access.