P a g e | 22
back on and display
shows a Fault message
Fault code 15 “ROOM
TEMPERATURE ABNORMAL”
is shown on the display
Remove built up dust from the
fireplace vents and replace
internal fan if necessary.
Fault code 15 “ROOM
TEMPERATURE ABNORMAL”
is shown on the display
Check the ambient room
temperature and make
changes to maintain it
between 65F-85F.
Keypad operates the
fireplace but the remote
control does not
Low Battery
Replace battery in remote
control with a 2032 coin-cell
Not aiming control correctly
Aim remote control to the
upper right of the viewing area
where sensor is located
Remote control defective
Replace remote control
Remote Sensor is defective
Replace remote sensor inside
fireplace
Aux heater does not
function and/or Fault
code 16 “AUX HEATER
FAILURE” is shown on
the display
Heater wiring is loose at
fireplace
Shutoff the breaker at the
breaker panel and check the
connections
Breaker panel connection is
loose or breaker is defective
Shutoff the breaker, check the
breaker panel connections,
verify voltages, and
tighten/replace as needed.