Before Mounting
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected]
Caution
If the camera’s power supply has been set to PoE Class 3
, you can attach modules
to the MxBus
and
USB connectors that do not exceed a total power consumption of
4 W. If the camera is using
PoE Class 2
,
the total power consumption of all attached
modules must not exceed 1 W!
For more information on changing the PoE class, please see
Section 2.5.7, «Variable
PoE»).
2.2.3 Network Connection with MOBOTIX Patch Cable
The supplied
MOBOTIX patch cable
can be used to connect the camera to an
MX-Patch-
Box
, an
MX-NPA-Box
or to a standard network port.
Connecting the Patch Cable to the Camera
First remove the blue bayonet catch and the blue sealing
plug in the left-hand connector on the S15. Then insert the
MOBOTIX patch cable into the camera and secure the cable
using the bayonet catch.
Connecting the Patch Cable to an MX-Patch-Box, MX-NPA-Box or
Standard Network Port
First remove the blue bayonet catch and the blue sealing
plug in the right-hand connector on the box to establish the
network connection to an MX-Patch-Box or MX-NPA-Box.
Then insert the MOBOTIX patch cable into the box and secure
the cable using the bayonet catch.
More information on installing an
MX-Patch-Box
or
MX-NPA-
Box
is available at
www.mobotix.com
under
Products >
Accessories > Functional Boxes
.
Insert the MOBOTIX patch cable of the S15 into the network port for standard connections
(only permitted in indoor areas).
Connecting Peripheral Devices (MxBus, Microphone, Speaker)
The opening provided for the installation cable must be used
for all other cables that are connected to the camera when
using the MOBOTIX patch cable. Depending on the cable
used, the single wire plug installed must be replaced with
one of the other cable plugs (M.4/5).
The cable used must be fixed to the circuit board using one of the cable ties supplied (M.9)
to ensure that less strain is placed on the cable. The individual cable wires must be fixed
on the screw clamps using the the screwdriver supplied (M.9).
When attaching modules
with a total power con-
sumption of more than
1 W (via MxBus/USB):
Max. ambient tempera-
ture +50°C/122°F
Patch cable
Patch cable
Further cables