122
/160
S15 Camera Manual: Operating the Camera
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
www.mobotix.com • [email protected]
3.2.5 Starting the Camera with the Factory IP Address
Under certain circumstances, you may have to reset the camera to its factory IP address.
This could be the case, for example, if the IP address has been lost or the camera does
not respond to the last known IP address. Proceed as follows to start up the camera with
its factory IP address:
1. If the camera is powered on, disconnect the power supply by unplugging the cor-
responding cables and then reconnect the power supply.
2. Wait until both LEDs light up simultaneously for the first time.
3.
Press the L key within the next four seconds and hold it down until the LED
next to the key is blinking three times
(if you need to try again, go back to Step 1).
4. If a speaker is attached to the camera, the camera emits a single sound
(“boing”)
after about 30 to 45 seconds
.
The camera has finished booting and can now be used (e.g., MxEasy, MxControlCenter,
MOBOTIX App, web browser).
Notes
If you use the camera’s
L key
to load the factory network configuration, this configu-
ration is not automatically saved in the camera’s flash memory. When the camera
is next rebooted without using the
L key
, the last stored network configuration will
be used. To permanently store the new network configuration in the camera’s flash
memory, open
Admin Menu > Store
.
As opposed to resetting the camera using
Admin Menu > Reset configuration to
factory defaults
, the user information will
not
be reset if the camera is booted using
the factory IP address.
Passwords and cam-
era settings will
not be changed
R
L
Make sure you store
the default network
configuration to the
permanent flash memory!