VAP Monitoring and Configuration
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual
65
If one or more alarms occur, the corresponding Status indicator will be illuminated in RED. If the
VAP is OK and no fault occurs, the
Overall Status
indicator will show GREEN.
Alarm
Description
DL Adjustment
RED - Cable (between VCU to VAP) is too long (over 100m/300ft)
Over Temperature
RED - Temperature of unit exceeds normal range
VAP Faulty
RED - A fault has been detected in the VAP
Overall Status
Indicates Fault (RED) level or GREEN if there are no faults
Note: DL adjustment alarm is raised when a VAP is connected over a cable exceeding system
cable length limitation. In such cases, the system continues to provide the wireless services, but
you should check the coverage of the VAP (as output power may be degraded due to excess
cable loss) and check the Ethernet connection (as Ethernet standard maximum cable length has
probably been exceeded).
8.3
VAP RF Parameters
The VAP
RF Parameters
sub-tab provides the configurable RF parameters corresponding to the
VAP element selected in the network topology tree. The displayed RF parameters are similar for
both MIMO and SISO service modes (in SISO service mode only
Channel 1
parameters are
displayed).
To View the VAP RF Parameters
Click the
Config
tab from the main menu bar and then select the VAP from the network
topology and click the
RF Parameters
sub-tab. The parameters displayed in RF tab correspond to
the selected element.
Selected VAP