VCU Unit Installation and Provisioning
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual
34
4.4.5
Provisioning the Slave VCUs
Note: The Slave VCUs management and configuration is performed through a remote connection
to the Master VCU, via the web management. Before provisioning the Slave VCUs verify that the
Master VCU unit, to which it is connected, has been provisioned (See section 4.4.1).
The Slave VCU RF parameters are set via the Master VCU, therefore there is no need to
configure the RF parameters individually for each connected Slave VCU. It is recommended to
assign each Slave VCU an identifiable name.
To Assign a Name to a Slave VCU:
1. Connect to the Master VCU unit (either locally as explained in section 4.4.1 or remotely) and
select the Slave VCU to be provisioned from the Network Topology Tree.
Each VCU has a default name of the form “VCUPx-name”, where:
Px
- Master VCU port number to which the Slave VCU is connected
Name
- User-defined name
2. To assign the Slave VCU an identifiable name:
Select the Module Info Tab
Click the
Modify
button
Type the unit name and click
OK
.
Note: Up to 17 alpha-numeric characters are allowed.
Selected Slave
VCU-
Click
Modify
to
Assign Name