VCU Unit Installation and Provisioning
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual
21
Figure 4-2. Master and Slave VCU Connections
3. Connect the Slave VCU
VAP
ports to the patch-panel that feeds the existing structured CAT-
5e/6 cabling system.
4. According to VAPs layout plan, as explained in section 3.4.2, connect the Ethernet switch
cables. (See section 4.3 for more detailed explanation).
If the requested jack is already in use, disconnect it from the Ethernet switch and re-
connect it to the corresponding
Ethernet
port in the Slave VCU front panel.
4.3
Ethernet Cable Connections to VAPs
This section describes the how to perform the relevant Ethernet LAN connections to the VAPs
from the VCUs via the Ethernet switch (See section 4.3.1) and provides a description of the PoE
transferred between the VCU and the VAPs. (See section 4.3.2).
4.3.1
Shifting Relevant Ethernet LAN Connections
For VAPs installed on currently ACTIVE Ethernet ports, shift the relevant Ethernet LAN
connections to the Ethernet ports on the Master or Slave VCU.