Twist flanges clockwise until small flanges snap over edges. The Twist Clip is now in
position.
Place stud through 1/2" knock-out. Use 4WN washer-nut combination and tighten
securely.
Figure 5-2. VAP Installed Horizontally on Ceiling
7. Continue to section 5.3.4 for connections and verifying normal operation.
5.3.3
Concrete/Wood Ceiling Installation
To Install VAP in Lowered Ceiling
1. Mark the location of the (4) screws on the ceiling according to the (4) larger holes on the
bracket assembly.
2. Drill the screws in to the marked locations on the ceiling.
3. Align the three screw holes of each of the brackets (Ceiling and Locke) as shown in the
adjacent figure and using the Flat Head Screws,
loosely
assemble the brackets.
Note: To be
adjusted at a later stage.