VCU Unit Installation and Provisioning
LTE 700 MHz MobileAccessVE Instant Coverage Solution User Manual
32
Note: To briefly check the VCU status, click on the VCU name in the Topology Tree. The VCU
icon will appear, showing the LEDs status.
2. Mask irrelevant alarm conditions to avoid affecting the overall status of the unit. See
following example.
For Example
Note: Channel DL signal refers to the MIMO/SISO DL signal from the BS side towards the
remote units (VAPs).
In the example below “Channel 2 RF DL Pwr High” alarm is masked (Disabled). This is the
alarm
for the DL signal (from the BS side)
.
The left dialog shows the alarm response when Channel 2 DL RF Pwr High alarm is enabled
and a fault corresponding to that alarm is detected. (MIMO 2 DL RF Power exceeds the
defined range). The overall status will be RED indicating a fault.
The right side dialog shows the alarm response when Channel 2 DL RF Pwr High alarm is
masked (Disabled). The Channel 2 DL RF Pwr High LED will appear RED; but, the overall
status will be GREEN, showing NO Fault.
Figure 4-3. Service2 Service Off Alarm
– Unmasked Figure 4-4. . Service2 Service Off Alarm –Masked
Overall Status RED
Click VCU Master
Overall Status GREEN