![Mobidiag Novodiag NVD-BCS-A NVD-TSCA-A Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/mobidiag/novodiag-nvd-bcs-a-nvd-tsca-a/novodiag-nvd-bcs-a-nvd-tsca-a_user-manual_1815166014.webp)
Novodiag® System User Manual (NVD-SYST-UM)
V4-0 – April 2020
10
Figure 8. Back view of the Novodiag® Instrument
The Novodiag® Instrument performs a self-diagnostic during the initialisation process. The status lights below
each slot allows to monitor the initialisation process shifting from orange (self-diagnostic ongoing) to green (ready
to use). The Table 4 describes the status lights meaning.
Table 4. Possible status lights on the Novodiag® Instrument
To shut down a standalone Novodiag® Instrument, switch off the power button. To shut down a stack, switch off
the power strip only.
NOTE Always remove Novodiag® Test Cartridges prior to shutting down the Novodiag® Instrument.
CAUTION
In a stack conformation (from 2 to 4 instruments), Novodiag® Instruments are interconnected.
Do not
shut down a Novodiag® Instrument separately, you risk impairing the whole stack functioning. Contact Mobidiag
representative for assistance.
WARNING!
In case of electrical hazard, shut down the whole stack and disconnect it from the power supply.
4.5.2.
Adjusting the Touchscreen Computer on Post or Arm
You can adjust the orientation of the Touchscreen Computer on the Post or on the Arm by unlocking the lever of
the ball mounting at the back of the Touchscreen Computer (see Figure 9), rotating the computer until getting
the desired orientation and then securing the lever back.
NOTE While unlocking the ball mounting lever, make sure to hold the Touchscreen Computer.
The Arm (stack conformation) can be further adjusted horizontally by using the two knobs. The first knob (Arm
rotation knob) allows to adjust the Arm rotation relative to the stack while the second knob (computer rotation
knob) allows the orientation of the Touchscreen Computer.
Signal
Meaning
Green light
The slot is available for running a new test.
Orange light
The slot is busy. Test or self-diagnostic is running.
Green light
blinking
The slot is waiting for action by the user. Experiment is completed.
Orange light blinking
The slot is waiting for action by the user. Transport cartridge in the slot.
Red light
The slot is failing.
No Light
The slot is either absent or disabled.