6.2.2
Switching the STL back on if the ambient temperature
falls below 0 °C
If the ambient temperature falls below 0 °C (e.g. during storage in a
warehouse or operation in a mobile sales cart), the STL triggers. The unit
cannot be switched on.
DANGER
Risk of injury due to the sensor bursting
The sensor tip may burst if it becomes overheated.
→
Never heat sensors with a lighter or similar source of heat.
1.
Warm the sensors to room temperature (20 °C).
2.
Remove the cap in the switch cover.
3.
Press the red unlocking button.
4.
Replace the cap in the switch cover.
6.3 Control lamp is defective
CAUTION
Equipment damage due to penetration of water
→
Replace control lamps according to the applicable replacement parts
list.
An unsealed lens or control lamp could allow penetration of cleansers.
Only put the defective unit back into service after replacing the defective
lens or control lamp with an original component.
27
Operating manual
Faults
Deep fat fryer (electric)