Creating Programs
Advanced Programs
Advanced programs offer all of the Dyad programming features with the exception of the
graphical programming interface. Creating an advanced program is desirable if you wish
to enter a program that:
• Contains many steps
• Contains temperature or gradient steps with modifying instructions (i.e., increment temp,
extend time, slow ramp, beep)
• Contains multiple goto steps
• Contains a temperature incubation in the range of –1
°
C to –5
°
C
• Contains an incubation lasting between 1 hour 40 minutes and 18 hours (incubation
times shorter than 1 hour 40 minutes and forever incubations are also allowed.)
While all graphical programs can be opened and edited in advanced mode, only a subset
of advanced programs can be opened and edited in basic mode. Advanced programs that
meet the criteria outlined above for graphical programs can be opened in basic mode (see
“Opening a Program” in Chapter 6 for more information).
To create an advanced program, refer to the “Entering a Program Using Advanced Mode”
section below.
Designing a New Program
The first step in designing any program is the translation of your experimental protocol into
Dyad program steps. We suggest writing all steps until you are reasonably comfortable with
Dyad programming.
For purposes of this explanation, we will be working with a cycle sequencing example. First,
we will write down the raw steps, then make some modifications with the parameters that
were described in the previous section, “The Elements of a Program”, and then determine
what our final program should be. The actual implementation and entering of program steps
will be covered in a later section.
Note:
You will soon become familiar with Dyad program design and be able to enter steps
directly from experimental protocols. However, we strongly suggest following these steps the
first few times through, as they will probably save troubleshooting time later.
Содержание DNA Engine Dyad PTC-220
Страница 8: ...1 4 DNA Engine Dyad Operations Manual ...
Страница 14: ...2 6 DNA Engine Dyad Operations Manual ...
Страница 38: ...4 18 DNA Engine Dyad Operations Manual ...
Страница 78: ...DNA Engine Dyad Operations Manual 5 40 ...
Страница 109: ...DNA Engine Dyad Operations Manual 8 10 ...
Страница 113: ...9 4 DNA Engine Dyad Operations Manual ...
Страница 127: ...DNA Engine Dyad Operations Manual 10 14 ...
Страница 136: ...11 9 Alpha Units and the Remote Alpha Dock System Figure 11 5 Flush mounting template ...
Страница 137: ...11 10 DNA Engine Dyad Operations Manual ...
Страница 142: ......
Страница 155: ...Index In 11 service 8 8 set date time 8 3 update soft 8 5 8 6 user name 8 3 V Virtual keyboard 5 18 W Warranties D 1 ...
Страница 156: ...DNA Engine Dyad Operations Manual In 12 ...
Страница 157: ...Declaration of Conformity DoC 1 ...