![Miyachi Unitek LMV700 Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/miyachi-unitek/lmv700/lmv700_operators-manual_1812773058.webp)
APPENDIX B: ELECTRICAL AND DATA CONNECTIONS
LMV700 Nd:YVO
4
LASER MARKER
B-2
990-545
Output Signals
Output Format:
Photo MOS output
Output Rating:
24 V DC, 70 mA max
Pin No.
Signal
Signal description
11
LD illuminated
Output turns
ON
when the LD is on;
OFF
when LD is off.
12 Marking
underway
Output
turns
ON
when the Marker is in the process of marking.
13 Marking
standby
(ready)
*1
Output
turns
ON
when the Marker is ready to Mark.
14
Laser error
Output turns
ON
when an internal error has occurred.
15
Data error
Output turns
ON
when marking data, battery, or memory errors occur.
16 Reserved
Do
not
use.
17 Temperature
warning
Output turns
ON
when the temperatures of any module is outside the normal
range. Output is
OFF
when all temperatures are within the normal range.
18 Standby
Output turns
ON
when the laser is first turned on indicating that all laser
systems are functional and have passed the power-on tests. Output also toggles
ON
after the LD cooling period is complete.
21
DO common
Common Output terminal for the output signals.
22 Count
up
Output turns
ON
when the serial counter reaches the end value. When the
serial counter is reset (to either the minimum or maximum value), the output
signal will toggle
OFF
.
*1 Marking standby is
OFF
during the marking process or when writing data to the internal memory.
Содержание LMV700
Страница 22: ......
Страница 34: ......
Страница 38: ......
Страница 55: ...APPENDIX A TECHNICAL SPECIFICATIONS LMV700 Nd YVO4 LASER MARKER 990 545 A 3 Section II Dimensions Control Unit ...
Страница 56: ...APPENDIX A TECHNICAL SPECIFICATIONS LMV700 Nd YVO4 LASER MARKER A 4 990 545 Marking Head ...
Страница 60: ...APPENDIX B ELECTRICAL AND DATA CONNECTIONS LMV700 Nd YVO4 LASER MARKER B 4 990 545 When Using Contact Signals ...
Страница 72: ......