CHAPTER 4: MAINTENANCE
LMV700 Nd:YVO
4
LASER MARKER
4-6
990-545
Air Filter Inspection and Replacement
Always inspect the air filters on the front of the Control Unit and side of the Oscillator before starting
the equipment. If these filters are dusty, clean by using a small vacuum.
Every 1-6 months, remove the air filter on the Control unit and wash in a mild detergent solution. (The
operating environment will determine the level of soiling.)
If the air filters become clogged, internal temperatures may rise, leading to operational malfunctions.
Keep the air filters clean.
Control Unit Air Filter
1. Remove the front cover by removing the
screws at the bottom and lifting.
2. Remove the fixtures by spreading the
four ends of the fixtures (circled in the
figure) in the directions shown by the
arrows.
3. Remove the air filter from the cover.
Clean the filter in a mild detergent
solution and allow to dry completely.
4. Remount the air filter on the front cover.
5. Insert the fixtures to secure the air filter.
Fixture
Front
cover
6. Re-attach the front cover to the Control Unit.
Oscillator Air Filter
1.
Remove the air filter cover by pulling
forward on the side finger tab.
2.
Use a vacuum cleaner to remove dust
from the filter.
3.
Re-attach the cover to the Oscillator.
Содержание LMV700
Страница 22: ......
Страница 34: ......
Страница 38: ......
Страница 55: ...APPENDIX A TECHNICAL SPECIFICATIONS LMV700 Nd YVO4 LASER MARKER 990 545 A 3 Section II Dimensions Control Unit ...
Страница 56: ...APPENDIX A TECHNICAL SPECIFICATIONS LMV700 Nd YVO4 LASER MARKER A 4 990 545 Marking Head ...
Страница 60: ...APPENDIX B ELECTRICAL AND DATA CONNECTIONS LMV700 Nd YVO4 LASER MARKER B 4 990 545 When Using Contact Signals ...
Страница 72: ......