(2) Operation error
In any of the following cases, an error occurs and the corresponding error code is
stored into the completion status area (S)+1.
Error code
Case resulting in operation error
161
The G(P).OGSTOR instruction was executed in the offset/gain
setting mode.
162
The G(P).OGSTOR instruction was executed consecutively.
163
The G(P).OGSTOR instruction was executed for the model that
differs from the model for which the G(P).OGLOAD instruction had
been executed.
(3) Program example
The following program is designed to read the offset/gain values of the
Q64RD/Q64RD-G mounted in the position of I/O number X/Y0 to X/YF when
M11 is turned ON.
Performs processing at abnormal completion
Control data setting
Offset/gain value restoration
Dedicated instruction
(GP.OGSTOR)