MPI <4G63>
ï
Troubleshooting
13D-84
Standard Wave Pattern
Observation conditions
Function
Special patterns
Pattern height
Variable
Variable knob
Adjust while viewing the wave pattern
Pattern selector
Display
Engine speed
Idle
Standard wave pattern
(V)
Point A
Point B
Solenoid back
electromotive
force
(Approx. 7
u
10 V)
Injector drive time
Power
voltage
Drive signal: ON
Drive signal: OFF
Time
50
0
Wave Pattern Observation Points
Point A: Height of solenoid back electromotive force
Contrast with standard wave pattern
Probable cause
Solenoid coil back electromotive force is low or doesn’t
appear at all.
Short in the injector solenoid
Point B: Injector drive time
D
The injector drive time will be synchronized with the
M.U.T.-
II/III
tester display.
D
When the engine is suddenly raced, the drive time will
be greatly extended at first, but the drive time will soon
match the engine speed.
When idling