MPI <4G63>
ï
On-vehicle Service
13D-97
INTAKE AIR TEMPERATURE SENSOR CHECK
1.
Disconnect the air flow sensor connector.
2.
Measure resistance between terminals No. 5 and No.
6.
Standard value:
13
ï
17 k
:
(at
ï
20
_
C)
5.3
ï
6.7 k
:
(at 0
_
C)
2.3
ï
3.0 k
:
(at 20
_
C)
1.0
ï
1.5 k
:
(at 40
_
C)
0.56
ï
0.76 k
:
(at 60
_
C)
0.30
ï
0.42 k
:
(at 80
_
C)
3.
Remove the air flow sensor
4.
Measure resistance while heating the sensor using a hair
drier.
Normal condition:
Temperature (
_
C)
Resistance (k
:
)
Higher
Smaller
5.
If the value deviates from the standard value or the
resistance remains unchanged, replace the air flow sensor
assembly.
6.
Install the air flow sensor and tighten it to the specified
torque.
Tightening torque: 8.8
r
1 N·m
Equipment side connector
Air flow sensor
Intake air temperature
sensor