ON-VEHICLE SERVICE
HEATER, AIR CONDITIONER AND VENTILATION
55-70
CHARGING
M1552001200362
1. With the handles turned back all the way (valve
closed), install the adaptor valve to the
low-pressure side of the gauge manifold.
2. Connect the charging hose (blue) to the adaptor
valve.
3. Connect the quick joint (for low-pressure) to the
charging hose (blue).
CAUTION
•
Use tools that are suited to R134a.
•
To install the quick joint, press section when
connecting, run your hand along the hose
while pressing to ensure that there are no
bends in the hose.
4. Connect the quick joint (for low-pressure) to the
low- pressure service valve.
NOTE: The low-pressure service valve should be
connected to the flexible suction hose.
5. Close the high and low-pressure valves of the
gauge manifold.
CAUTION
Be sure to connect the power plug of the vacuum
pump to the vacuum pump adapter, and then
connect the power plug of the adapter to a 100-V
outlet.
6. Install the vacuum pump adaptor to the vacuum
pump.
7. Connect the charging hose (yellow) to the R-134a
connection port of the vacuum pump adaptor.
8. Tighten the adaptor valve handle (valve open).
9. Open the low-pressure valve of the gauge
manifold.
10.Turn the power switch of the vacuum pump to the
ON position.
NOTE: Even if the vacuum pump power switch is
turned ON, the vacuum pump will not operate
because of the power supply connection in step
(6).
CAUTION
Do not operate the compressor for evacuation.
11.Turn the vacuum pump adaptor switch to the
R134a side to start the vacuum pump.
12.Evacuate to a vacuum reading of 100 kPa or
higher (takes approx. 10 minutes).
AC212526AB
A
Sleeve
Low-pressure
service valve
Quick
joint
(for low
pressure)
Switch
Vacuum
pump
Power supply
plug
Vacuum
pump
adaptor
R-12
connection
port
Charging hose
(blue)
Adapter
valve
Charging hose
(yellow)
Gauge manifold
Switch
R-134a
connection
port
Low-pressure
valve
High-pressure
valve
AC212535
Vacuum
pump
Low-pressure
service valve
AB
Vacuum pump
adaptor switch
Содержание Lancer 2004
Страница 22: ...NOTES ...
Страница 34: ...NOTES ...
Страница 84: ...NOTES ...
Страница 138: ...NOTES ...
Страница 139: ...35 1 GROUP 35 SERVICE BRAKES CONTENTS BASIC BRAKE SYSTEM 35A ANTI SKID BRAKING SYSTEM ABS 35B ...
Страница 140: ...NOTES ...
Страница 180: ...NOTES ...
Страница 188: ...NOTES ...
Страница 218: ...NOTES ...
Страница 278: ...NOTES ...
Страница 423: ...23 1 GROUP 23 AUTOMATIC TRANSMISSION CONTENTS AUTOMATIC TRANSMISSION FF 23A AUTOMATIC TRANSMISSION OVERHAUL 23B ...
Страница 424: ...NOTES ...
Страница 425: ...22 1 GROUP 22 MANUAL TRANSMISSION CONTENTS MANUAL TRANSMISSION FF 22A MANUAL TRANSMISSION OVERHAUL 22B ...
Страница 426: ...NOTES ...
Страница 427: ...21 1 GROUP 21 CLUTCH CONTENTS CLUTCH 21A CLUTCH OVERHAUL 21B ...
Страница 428: ...NOTES ...
Страница 480: ...NOTES ...
Страница 481: ...00 1 GROUP 00 GENERAL CONTENTS GENERAL 00 GENERAL ELECTRICAL 00E ...
Страница 482: ...NOTES ...
Страница 514: ...NOTES ...
Страница 534: ...NOTES ...
Страница 638: ...NOTES ...