8
-
3. Others
(1) Reactor
installation
If it is necessary to improve the power factor, or if it is necessary to install the hoist just
below a high-voltage power supply unit (1,000 kVA or more, cable length = 10 m or less),
be sure to install a reactor. Without a reactor, the inverter may be damaged.
To install a reactor, please contact us.
(2) Measures for noises
There are several types of noises. The noise sent from
the external unit may cause abnormal operation of the
inverter. The noise generated by the inverter may be
sent back to the power supply line. The radiated noise
may cause abnormal operation of the peripheral units.
●
Suppression of noise sent from external units
Install a surge killer on each peripheral unit that may
generate large noise.
●
Suppression of noise generated by inverter
We recommend use of noise filter SF1259 or SF1260.
(Refer to the catalog of the Mitsubishi optional
general inverter of separate type.)
Characteristics of Noise Filter
Model
Applicable
hoist
Outside dimensions (Unit: mm)
Approximate weight
(kg)
Loss
(W)
Leakage current
(Ref. value)
(mA)
W H D
W1
H1
C
200 V
SF1259
U2-1/2 - 2
142
410
65
105
386
6
2.4
27
33
SF1260
U2-2.8 - 5
222
468
80
190
449
7
5
118
440
<Measures against leakage current>
This hoist uses an inverter to drive the
motor. Since high harmonics is included
in the inverter output voltage, leakage
current to the ground is created due to the
capacitance to the ground of the line from
the inverter to the motor and the floating
capacitance between the motor winding
and the iron core.
The leakage current not only flows through its own line of the inverter but penetrates other lines
through the ground wiring. To avoid malfunction due to the leakage current, use an earth
leakage circuit breaker with rated sensitivity current of 100 mA or greater. In this case, the
earth leakage circuit breaker functions to prevent disasters such as a fire due to leakage current.
2 mm
dia hole
Dimensional outline drawing
Earth leakage
circuit breaker
Inverter
Power supply
Motor
Leakage current
to the earth
Hoist
Содержание UM 10t
Страница 51: ... 47 Structural Drawing of Hoist Main Body 5t 10t PA00531 ...
Страница 52: ... 48 Structural Drawing of Electric Traversing Unit Monorail Type 10t P288922 ...
Страница 53: ... 49 Structural Drawing of Electric Traversing Unit Double rail type 5t PA00483 ...
Страница 54: ... 50 Structural Drawing of Traversing Mortor Double rail type 10t P276926 ...
Страница 55: ... 51 Structural Drawing of Hook Block 5t PG49975 ...
Страница 56: ... 52 Structural Drawing of Hook Block 10t PG49976 ...
Страница 60: ...MITSUBISHI ELECTRIC FA INDUSTRIAL PRODUCTS CORPORATION Specifications subject to change without notice ...