2-15
Installation
2Unpacking to Installation
The procedure of connecting the machine cable is shown
below. (Although the figure of the robot arm is the example of
RH-6FH of our company, it is the same)
1) Make sure that the power switch on the front of the
controller is turned OFF.
2) Connect the machine cable to its corresponding connector
on the robot arm side.
3) After connecting the connector, insert the hook attached
to the connector on the machine cable side to the rear of
the projection of the robot arm connector to fix securely in
place.
To remove the cable, insert a minus screwdriver into the hook
while padding with a cloth, and remove the cable by lifting the
hook.
The machine cable connectors are dedicated for the controller side and robot arm
side, so take special care when connecting.
If connected incorrectly, the connector pins could bend or break. Thus, even if
connected correctly, the robot will not operate correctly, creating a dangerous
situation.
Take special care to the leading of the connection cable. If the cable is pulled with
force or bent excessively, wires could break or the connector could be damaged.
Connect the machine cable at the place without the effect of the dust or oil mist.
Please keep the dust and oil mist from being applied to of the robot-arm connector
section, in the condition that the machine cable is removed. Since it becomes the
cause of failure.
Please be careful not to catch the hand at installation and removal.
固定フック
突起部
固定フック
機器間ケーブル側コネクタ
ロボット本体
ロボット本体側コネクタ
突起部
Robot arm
Connector on the
robot arm side
Hook
Projection
Connector on the
machine cable side
Hook
Projection
CAUTION
Be careful not to get your hand
pinched.
Hook
Minus screwdriver
Padding
Projection
CAUTION
When installing or removing the connector, to the connector
of the other party in parallel, install or remove. If load strong
against one side is applied, the connector pin may be
damaged and it may not be connected securely.
CAUTION
CAUTION
CAUTION
CAUTION