5 Maintenance and Inspection
Resetting the origin 5-114
8) Setting of the origin is completed.
9) Refer to
Page 130, "5.6.5 Recording the origin
in this manual, and record the origin data
on the origin data seal.
<ORIGIN> MECH COMPLETED
J1( ) J2(
1
) J3( )
J4( ) J5( ) J6( )
J7( ) J8( )
CLOSE
123
◇◆◇ Release the brake ◇◆◇
Do cursor movement into the parenthesis of each axis by the arrow key. The brakes can be released only for
the axis for which a "1" is displayed on the screen. If the brakes are not to be released, press the [0] key and
display a "0". If the [F1] key on the teaching pendant or the enabling switch is detached while the brakes are
released, the brakes will be work immediately.
◇◆◇ Select the axis of origin setting ◇◆◇
Do cursor movement into the parenthesis of each axis by the arrow key. The origin is set only for the axis for
which a "1" is displayed on the screen. If the origin is not to be set, press the [0] key and display a "0".