15
Unit: mm<in>
PUZ-A24NHA7 PUZ-A30NHA7
PUY-A24NHA7
PUY-A30NHA7
PUZ-A24NHA7-BS
PUZ-A30NHA7-BS
PUY-A24NHA7-BS
PUY-A30NHA7-BS
Drain hole (5-
ø33<1-5/16>)
Bottom piping hole (knockout)
145
<5-23/32>
145
<5-23/32>
145
<5-23/32>
220
<8-21/32>
30
<1-3/16>
81<3-3/16>
219<8-5/8>
71
<2-13/16>
71
<2-13/16>
Rear piping cover
Front piping cover
2-12×36 oval holes (Foundation Bolt M10<W3/8>)
Air Discharge
Rear Air
Intake
Side Air
Intake
2-U Shaped notched holes (Foundfation Bolt M10<W3/8>)
Installation Feet
330<13>
175
<6-7/8>
57
<2-1/4>
41
<1-5/8>
417<1-1/32>
28<1-3/32>
370<14-9/16>
19<3/4>
25<31/32>
70
<2-3/4>
175
<6-7/8>
600
<23-5/8>
40
<19/32>
53
<2-3/32>
61
<2-13/32>
0
Side Air
Intake
Handle for moving
Air Intake
Rear Air
Intake
Handle for moving
Min.100mm <3-15/16>
Min. 500mm <19-1
1/16>
2
1
Handle for moving
Handle for moving
Service panel
Earth terminal
Left
...
Power supply wiring
Reight
...
Indoor/Outdoor wiring
Terminal Connections
669<26-1
1/32>
950
<37-13/32>
322
<12-1
1/16>
943<37-1/8>
473<18-5/8>
23<29/32>
*1 447
<17-5/8>
*1 431
<16-31/32>
Min. 10mm
<3/8>
Min. 10mm
<3/8>
FREE
When installing the conduit,
Set the attachment to the
inner side of each panel.
1/2 Conduit attachment
2-ø22.2<7/8>
31<1-7/32>
74<2-19/32>
40<1-9/16>
2
1
...
Refrigerant GAS pipe connection (FLARE)
ø15.88(5/8F)
...
Refrigerant LIQUID pipe connection (FLARE)
ø 9.52(3/8F)
*1
...
Indication of ST
OP
V
AL
VE connection location.
Example of Notes
Power supply wiring hole (2-
ø27<1-1/16>knockout)
Rear trunking hole (knockout)
Rear piping hole (knockout)
63<2-1/2>
73<2-7/18>
23<29/32>
55<2-3/16>
27<1-1/16>
92
<3-5/18>
65
<2-9/16>
45
<1-25/32>
40
<1-9/16>
ø92
<3-5/8>
Power supply wiring hole (2-
ø27knockout)
Front trunking hole (knockout)
Front piping hole (knockout)
45
<1-25/32>
65
<2-9/16>
92
<3-5/8>
40
<1-9/16>
63<2-1/2>
23<29/32>
73<2-7/8>
55<2-3/16>
27<1-1/16>
92
<3-5/8>
Right piping hole (knockout)
Right trunking hole (knockout)
Power supply wiring hole (2-
ø27knockout)
19
<3/4>
55
<2-3/16>
23<29/32>
27
<1-1/16>92
<3-5/8>
92
<3-5/8>
40
<1-9/16>
75
<2-31/32>
73<2-7/18>
63<2-1/2>
92
<3-5/8>
Piping knockout Hole Details
Max.
<Foundation bolt height>
30<1-3/16>
Min.
Min.
Service space
10
<13>
Min.
500
<19-1
1/16>
500<19-1
1/16>
100<3-15/16>
Min.
Dimensions of space needed for service access are shown in the below diagram.
Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts. (Bolts and washers must be purchased locally
.)
Piping and wiring connections can be made from 4 directions: FRONT
,Right,Rear and Below
.
4 PIPING-WIRING DIRECTIONS
3 FOUNDA
TION BOL
TS
2 SER
VICE SP
ACE
1 FREE SP
ACE (Around the unit)
The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc.
ø
ø
FOUNDA
TION
OCH636A
Содержание PUY-A12NKA7
Страница 119: ...119 OCH636A ...