Caution
●
Only the display lights when the unit is stopped and power supplied to the unit.
●
When power is turned ON for the first time the (CENTRAL CTRL) display appears to go off momentarily but this is not a
malfunction.
●
When the central control remote control unit, which is sold separately, is used the ON-OFF button,
button and
TEMP button do not operate.
●
“NOT AVAILABLE” is displayed when the
button are pressed.This indicates that this room unit is not equipped with
the fan direction adjustment function and the louver function.
FILTER
CHECK MODE
TEST RUN
Operation lamp
This lamp lights during operation,
goes off when the unit stops and
flashes when amalfunction occurs.
CENTRALLY
CONTROLLED display
This indicates when the unit is con-
trolled by optional features such as
central control type remote controller.
display
This indicates when the continous
operation and time operation modes
are set.
It also display the time for the timer
operation at the same time as when
it is set.
OPERATION MODE display
This indicates the operation mode.
STANDBY display
This indicates when the standby
mode is set from the time the sleep
operation starts until the heating air
is discharged.
DEFROST display
This indicates when the defrost oper-
ation is performed.
CHECK display
This indicates when a malfunction
has occurred in the unit which should
be checked.
display
This lamp lights when electricity is
supplied to the unit.
display
This displays the selected setting
temperature.
display
The current time , start time and stop
time can be displayed in tensecond
intervals by pressing the time switch
button. The start time or stop time is
always displayed during the timer
operation.
display
The selected fan speed is displayed.
●
Display
display
The temperature of the suction air is
displayed during operation. The dis-
play range is 8° to 39°C. The display
flashes 8°C when the actual temper-
ature is less than 8° and flashes
39°C when the actual temperature is
greater than 39°C.
In this display example on the bot-
tom left, a condition where all dis-
play lamps light is shown for expla-
nation purposes although this differs
from actual operation.
display
This display lights in the check mode
or when a test operation is per-
formed.
CHECK MODE
TEST RUN
display
This lamp lights when the filter need
to be cleaned.
FILTER
display
This displays the air
direction.