15
OUTLINES AND DIMENSIONS
5
1. INDOOR UNIT PLH-3GK(H)B
1
.UK
Unit : mm (inch)
35(1-3/8)
75(2-15/16)
55(2-5/32)
Inspection hole
(drain water lift-up mechanism)
Refrigerant pipe(15.88
mm
dia.)
flared connection 5/8F
flared connection 3/8F
62(2-7/16)
160(6-5/16)
220(8-21/32)
250(9-27/32)
Refrigerant pipe (9.52
mm
dia.)
A
Drain pipie VP-25
connection
Suspension bolt pitch
Suspension bolt pitch
785(30-29/32)
TERMINAL BLOCK
TERMINAL BLOCK
30(1-3/16)
(Drain pipe inserting length
)
60(2-3/8)
66(2-19/32)
192(7-9/16)
192(7-9/16)
820(32-9/32)
820(32-9/32)
72(2-27/32)
530(20-7/8)
192(7-9/16)
192(7-9/16)
890(35-1/32)Ceiling hole
890(35-1/32)Ceiling hole
30(1-3/16)
30(1-3/16)
30(1-3/16)
30(1-3/16)
Wiring arrangement
opening
A
Branch duct hole (knock out hole)
Bar ring hole
Ceiling side
70-85
Suspension bolt
lower edge
61
61
104
104
w
298(11-23/32)
45
25
190
110
5
65
12- 2.8
65
100
Suspension boltM10
or W3/8
w
Note that the space between the ceiling
panel of the unit and ceiling slab must be
10 to 15
mm
to be left.
300(11-13/16)
587(23-1/8)
<Air intake hole>
Grill
4-Auto vane
<Air outlet hole>
<Air outlet hole>
587(23-1/8)
587(23-1/8)
Air intake grill
53(2-3/32)
80(3-5/32)
587(23-18)
<Air outlet hole>
950(23-1/8)
Vane motor
Wiring arrangement
opening side
950(37-13/32)
80(3-5/32)
53 (2-3/32)
Refrigerant piping side
High efficiency
filter(option)
175(6-7/8)<245(245(9-21/32)>
65(2-9/16)<135(5-5/16)>
363(14-9/32)<433(17-1/16)>
45(1-25/32)
Wiring arrangement
opening side
Intake grille opening/
closing side(Factory setting)
(Ckanged by 90
)
Intake grille opening/
ciosing side
(Factory setting)
Refrigerant piping side
Note
1. For drainage piping use VP-25 PVC piping.
2. For suspension bolts use M10 or W3/8 screws.
3. Figure 890X890 ceiling holes are standard but the ceiling holes for
860X860-910X910 can also be installed.
4. If installing the optional high ef
ficiency filter element (filter casement),the
dimension between the transom and ceiling should be more than
365mm.
5. If installing the optional fresh air intake casement, the dimension
between the transom and ceiling should be more than 435mm.
6.
The intake grill and its air filter´s opening /closing direction can be
changed. See table 1.
<Dimensions inside parentheses apply to installing the optional fresh air
intake casement.>
Intake gnill
Intake air filter
O
O
X
X
Changed by 90°
Changed by 180°
<
T
able 1
>
Содержание PLH Series
Страница 2: ......