Suspension bolt pitch
Suspension bolt pitch
1305(51-3/8)
TERMINAL BLOCK
TERMINAL BLOCK
30(1-3/16)
(Drain pipe inserting length
)
60(2-3/8)
66(2-19/32)
192(7-9/16)
192(7-9/16)
1340(52-3/4)
820(32-9/32)
77(3-1/32)
530(20-7/8)
192(7-9/16)
192(7-9/16)
890(35-1/32)Ceiling hole
1410(55-1/2) Ceiling hole
30(1-3/16)
30(1-3/16)
30(1-3/16)
30(1-3/16)
Wiring arrangement
opening
A
w
Note that the space between the ceiling
panel of the unit and ceiling slab must be
10 to 15
mm
to be left.
1107(43-19/32)
<Air intake hole>
Grill
4-Auto vane
<Air outlet hole>
<Air outlet hole>
587(23-1/8)
587(23-1/8)
53
1107(43-19/32)
<Air outlet hole>
1470(57-7/8)
Vane motor
Wiring arrangement
opening side
950(37-13/32)
80(3-5/32)
53 (2-3/32)
Refrigerant piping side
Branch duct hole (knock out hole)
Bar ring hole
Ceiling side
70-85
Suspension bolt
lower edge
61
61
104
7 104(=728)
w
298(11-23/32)
45
25
190
110
5
22- 2.8
Suspension boltM10
or W3/8
442(17-13/32)
410(16-5/32)
410(16-5/32)
300(11-13/16)
100
65
65
Do not peel off
the insulation here.
Leave this bar ring hole.
Intake grill opening/
closing side(Factory setting)
Air intake grill
80
35(1-3/8)
75(2-15/16)
55(2-5/32)
Inspection hole
(drain water lift-up mechanism)
Refrigerant pipe(19.05
mm
dia.)
flared connection 3/4F
flared connection 3/8F
62(2-7/16)
160(6-5/16)
220(8-21/32)
250(9-27/32)
Refrigerant pipe (9.52
mm
dia.)
A
Drain pipie VP-25
connection
High efficiency
filter(option)
175(6-7/8)<245(245(9-21/32)>
65(2-9/16)<135(5-5/16)>
363(14-9/32)<433(17-1/16)>
45(1-25/32)
Note
1. For drainage piping use VP-25 PVC piping.
2. For suspension bolts use M10 or W3/8 screws.
3. Figure 890X1,410 ceiling holes are standard but the ceiling holes for
860X1,380-910X1,430 can also be installed.
4. If installing the optional high ef
ficiency filter element (filter casement),the
dimension between the transom and ceiling should be more than
365mm.
5. If installing the optional fresh air intake casement, the dimension
between the transom and ceiling should be more than 435mm.
6.
The intake grill and its air filter´s opening /closing direction can be
changed. See table 1.
<Dimensions inside parentheses apply to installing the optional fresh air
intake casement.>
Intake gnill
Intake air filter
X
X
O
O
Changed by 90°
Changed by 180°
<
T
able 1
>
Unit : mm (inch)