<How to operate>
To change the air flow direction, press
button.
NOTE: Discharge direction can be set by the indoor dipswitch SW5-3.
Dipswitch
SW5-3:OFF
1
35°
2
45°
3
55°
4
65°
SW5-3:ON
20°
35°
45°
65°
(1) COOL/DRY operation
At the start-up of COOL or DRY operation, the airflow direction in automatically set to 35°/20°. After, it can be changed to
another direction with
button on the remote controller.
<Auto return>
When 55°/45° or 65°/65° airflow is set with fan speed in LOW, “AUTO RETURN” appears below the room temperature dis-
play. One hour later the direction changes to 35/20 degrees, automatically and “AUTO RETURN” disappears.
(2) HEAT operation
At the start-up of HEAT operation, airflow direction depends on the setting of the last operation.
After, it can be changed to another direction with
button. The airflow direction shifts to 35°/20° regardless of the
remote controller settings under any of the following conditions.
●
Thermostat OFF
●
Defrosting
●
Indoor fan speed EXTRA-LOW in hot adjustment
Available in COOL operation with fan speed on HIGH or
in HEAT operation.
Unavailable in DRY operation.
If fan speed changes from LOW to HIGH during 45°/35°
downward airflow in COOL mode, the direction automat-
ically changes to 35°/20°.
35 /20
1
45 /35 downward
2
55 /45 downward
3
65 /65 downward
4
swing
5
2-5 Auto vane control
Changes by press-
ing the
button.