![Mitsubishi Electric MSC-CA20VB Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/mitsubishi-electric/msc-ca20vb/msc-ca20vb_service-technical-manual_1810424023.webp)
23
EMERGENCY OPERATION switch
Press once <Cool>
Press again <Stop>
OPERATION INDICATOR lamp
• The following indication applies regardless of
shape of the indicator.
Lighted
Not Lighted
2-8. EMERGENCY / TEST OPERATION
In case of test run operation or emergency operation, use EMERGENCY OPERATION switch on the front of the indoor
unit. Emergency operation is available when the remote controller is missing, has failed or the batteries of remote con-
troller run down. The unit will start and OPERATION INDICATOR lamp will light.
The first 30 minutes of operation is the test run operation. This operation is for servicing. The indoor fan speed runs at
High speed and the system is in continuous operation. (The thermostat is ON.)
After 30 minutes of test run operation, the system shifts to EMERGENCY COOL MODE with a set temperature of 24°C.
The fan speed shifts to Med. speed.
The coil frost prevention works even in emergency operation.
In the test run or emergency operation, the horizontal vane operates in VANE AUTO (
) mode.
Emergency operation continues until EMERGENCY OPERATION switch is pressed again or the unit receives any
signal from the remote controller. In case of latter, normal operation will start.
NOTE : Do not press EMERGENCY OPERATION switch during normal operation.
PROGRAM TIMER
(Example 1) The current time is 8:00 PM.
The unit turns off at 11:00 PM, and on at 6:00 AM.
• OFF timer and ON timer can be used in combination.
• “
” and “
” display shows the order of OFF timer and ON timer operation.
(Example 2) The current time is 11:00 AM.
The unit turns on at 5:00 PM, and off at 9:00 PM.
NOTE : TIMER setting will be cancelled by power failure or breaker functioning.
PM
AM
PM
PM
OBT06D--1qxp 07.3.2 9:22 AM Page 23