The table below shows the role of Exclusive LEV and Receiver LEV in each operation mode.
w
In COOL mode, the two indoor coil thermistor (one main and one sub) sense temperature ununiformity (superheat) at the
heat exchanger, and when temperature difference have developed, the indoor coil thermistors adjust LEV opening to dimin-
ish the superheat.This action is called Evaporation Temperature Protection.
Circulation
Amount
Control
High
Pressure
Protection
w
Evaporation
Temperature
Protection
Discharge
Temperature
Protection
Capacity
Distribution
COOL
Exclusive LEV
Receiver LEV
Exclusive LEV
Receiver LEV
HEAT
Indoor heat
exchanger
Outdoor
heat
exchanger
Exclusive
LEV
Receiver
LEV
Receiver
(MXZ-4A71VA, MXZ-4A80VA- )
E1
The opening pulse of the Receiver LEV is fixed to the standard No.3 in cooling operation, and so is that of each Exclusive
LEV in heating operation.
However the opening pulse will be changed to the standard No.4 or No.5 when the discharge temperature protection or high-
pressure protection is working.
In addition to that, it will also be changed to standard No.2 or No.1 when the opening pulse of the each Exclusive LEV
becomes 100 pulse or less in cooling operation or so does that of Receiver LEV in heating operation.
1
2
3
4
5
200
300
400
450
500
Standard No.
Number of
operating
indoor units
<MXZ-3A54VA MXZ-4A71VA>
1 unit
150
320
360
410
500
2 units
250
320
370
420
500
3 units
250
320
380
430
500
4 units
(MXZ-4A71VA)
4 units
(MXZ-4A71VA)
120
140
160
220
280
1 unit
120
140
160
220
280
2 units
120
140
160
220
280
3 units
120
140
160
220
280
COOL
LEV opening (pulse)
HEAT
1
2
3
4
5
150
250
350
400
450
Standard No.
Number of
operating
indoor units
<MXZ-4A80VA- >
1 unit
250
320
360
410
460
2 units
250
320
370
420
470
3 units
250
320
380
430
480
250
300
450
460
470
1 unit
250
300
380
400
450
2 units
250
300
380
390
440
3 units
4 units
4 units
240
290
380
390
430
COOL
LEV opening (pulse)
HEAT
E1
MXZ-3A/4A71/4A80VA
-
E1
• The standard opening is on the straight line, which connects an each standard point in the section where divided
into seven according to the operation frequency of compressor as shown in the figure below.
(LEV opening is controlled in proportion to the operation frequency.)
Note: Opening is adjusted at the standard opening according to the indoor unit conditions.
However, inclination of standard opening in each point of opening does not change with the original curve.
Determination of LEV standard opening in each indoor unit
OBT06D--6qxp 07.3.2 10:16 AM Page 154