10
3. Operation
Ŷ
0DQXDOYDQHDQJOH:LUHGUHPRWHFRQWUROOHU
F1
F2
F3
F4
Main
Main display:
Cursor
Page
Main menu
Maintenance
Initial setting
Service
F1
F2
F3
F4
Maintenance menu
Main menu:
Cursor
Auto descending panel
Manual vane angle
3D i-See sensor
F1
F2
F3
F4
Manual vane angle
Input display:
Cur.
Address
Check
Ref. address
Unit No.
Identify unit Check button
F1
F2
F3
F4
Manual vane angle
Manual vane angle
Select:
Setting
Outlet
Angle
Note:
Do not set the draft reduction in an environment with high humidity.
Otherwise, condensation may form and drip.
1
Select “Maintenance” from the
Main menu (refer to page 8), and
press the [SELECT] button.
2
Select “Manual vane angle” with
the [F1] or [F2] button, and press
the [SELECT] button.
3
Move the cursor to “Ref. address”
or “Unit No.” with the [F1] button to
select.
Select the refrigerant address and
the unit number for the units to
ZKRVHYDQHVDUHWREH¿[HGZLWK
the [F2] or [F3] button, and press
the [SELECT] button.
5HIDGGUHVV5HIULJHUDQWDGGUHVV
8QLW1R
3UHVVWKH>)@EXWWRQWRFRQ¿UPWKH
unit.
The vane of only the target indoor
unit is pointing downward.
4
The current vane setting will ap-
pear.
Select the desired outlets from 1
through 4 with the [F1] or [F2] but-
ton.
2XWOHW³´³´³´³´DQG³
4, (all outlets)”
Press the [F3] or [F4] button to go
through the option in the order of
“No setting (reset)”, “Step 1”, “Step
2”, “Step 3”, “Step 4”, “Step 5” and
“Draft reduction*”.
Select the desired setting.
* Draft reduction
7KHDLUÀRZGLUHFWLRQIRUWKLVVHWWLQJ
LVPRUHKRUL]RQWDOWKDQWKHDLUÀRZ
direction for the “Step 1” setting in
order to reduce a drafty feeling.
The draft reduction can be set for
only 1 vane.
Ŷ
Vane setting
Press the [SELECT] button to save the settings.
A screen will appear that indicates the setting information is being trans-
mitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 5) when
the transmission is completed.
Make the settings for other outlets, following the same procedures.
If all outlets are selected,
will be displayed the next time
the unit goes into operation.
Navigating through the screens
To go back to the Main menu ................ [MENU] button
To return to the previous screen .......... [RETURN] button
Ŷ
0DQXDOYDQHDQJOH:LUHOHVVUHPRWHFRQWUROOHU
Fig. 1
A
Fig. 2
B
Fig. 3
Step 1
Step 2
Step 3
No setting
Draft
reduction*
All outlets
Step 5
Step 4
1
Going to the Manual vane setting
mode
Press
the
button.
(Start this operation from the status
of remote controller display turned
off.)
“FUNCTION” is lighted and “1”
blinks. (Fig. 1)
Press
the button to select “2”,
and then press the
button.
2
Selecting the vane number (Fig. 2)
Press
the buttons to select the
vane number
A
, and then press
the
button.
3
Setting the vane angle (Fig. 3)
Press
the buttons to select the
vane angle
B
.
Point the wireless remote controller
toward the receiver on the indoor
unit, and then press the
button.
Display
Setting
Step 1
Step 2
Step 3
Step 4
Display
No display
Setting
Step 5
No setting
Draft reduction*
* The draft reduction can be set for only 1 vane.
The setting is enabled only for the last vane that was set.
BH79A366H01_en.indd 10
11/28/2017 1:31:18 PM