144
Sequence instructions
Note the following when nesting the instructions.
(1) The instructions can be nested to a level of eight (N0 to 7). When nesting them,
use MC from lower to higher nesting (N) numbers and MCR from higher to lower
numbers. In the opposite order, the PLC function cannot perform normal
operation since the instructions cannot be nested.
(2) When the MCR instructions are gathered in one place in the nesting structure, all
master controls can be terminated by one lowest nesting (N) number.
Since buses cross each other, normal
master control ladder cannot be created.
A
B
Display in ladder mode
Nesting numbers of MCR are
opposite.
Actual operation ladder
Содержание FR - F700
Страница 1: ...INVERTER FR F700 FR F 700 INVERTER PLC FUNCTION PROGRAMMING MANUAL ...
Страница 7: ...VI MEMO ...
Страница 131: ...124 Sequence instructions Program Examples LD LDI AND ANI OR ORI ORB ANB Coding Coding Coding ...
Страница 207: ...200 MEMO ...
Страница 208: ...201 Chapter 1 Chapter 2 Chapter 3 Chapter 4 4 ERROR CODE LIST 4 1 How to read the error code 202 ...
Страница 211: ...204 MEMO ...
Страница 212: ...205 APPENDIX Appendix 1 Instruction processing time 206 ...
Страница 216: ...FR F 700 INVERTER ...