4. Setting up MELDASMAGIC64 System
4.3 Setting Up NC Card and Device Driver (ISA Card)
51
Settings of the IRQ rotary switch
Enable IRQ
Switch on the NC Card
(IRQ)
None 0
IRQ5 1
IRQ7 2
IRQ9 4
IRQ10 8
Settings of the IOPADR rotary switch
I/O port address
Switch on NC Card
(IOPADR)
I/O port address
Switch on NC Card
(IOPADR)
120-123 0 220-223 8
140-143 1 240-243 9
160-163 2 260-263 A
180-183 3 280-283 B
1A0-1A3 4 2A0-2A3 C
1C0-1C3 5 2C0-2C3 D
1E0-1E3 6 2E0-2E3 E
200-203 7 300-303 F
Settings of the DPADR rotary switch
2-port memory
Switch on the NC Card
(DPADR)
D8000 - DFFFF
0
D0000 - D7FFF
1
C8000 - CFFFF
2
C0000 - C7FFF
3
Mount NC Card on the personal computer.
[Procedures]
(1) Mount the battery on NC Card.
(2) Attach NC Card to the personal computer’s ISA bus.
(3) Connect peripheral devices.
* For the details of NC Card mounting and peripheral device connection, refer to “Connection Manual
(BNP-B2203).”
Downloaded from