4. Setting up MELDASMAGIC64 System
4.3 Setting Up NC Card and Device Driver (ISA Card)
50
4.3.2.2 Mounting NC Card
Mount NC Card according to the procedures below.
!
CAUTION
Be sure to unplug the personal computer before mounting NC Card. In case this operation is
executed with the power on, the devices may be damaged.
Set the rotary switch on NC Card.
[Procedure]
(1) Refer to the following table of correspondence between NC Card layout and rotary switch settings,
and set the DPADR, IOPADR, and IRQ settings of the rotary switch to the resource settings of the
personal computer of which you made a note in chapter 4.3.2.1 “Installing NC System Device
Driver.”
BAT
SODIMM1
SODIMM2
CIO
CF6
1
CF
1
0
Symbol
Description
No. of pins
Factory setting
CIO
Expansion IO connector
80 pins
-
CF61
Connector relay board connection connector
26 pins
-
CF10
Connector relay board connection connector
50 pins
-
ISA
ISA bus connector
-
DPADR ISA bus address selection
0
IOPADR IO port address selection
0
IRQ
Interrupt number selection
0
CF61
CIO
CF10
IOPADR
IRQ
HR621B card layout
DPADR
ISA
ISA
BAT
IR Q
DPADR
CIO
CF
6
1
CF1
0
DPADR
HR623C card layout
ISA
ISA
CF61
CIO
CF10
IRQ
IOPADR
Downloaded from